Dimensions Unlimited 12X16B3R4T Скачать руководство пользователя страница 23

 

 

 

Dimensions Unlimited 

23 

Warranty 

 

SHIPPING TERMS:

 

F.O.B. St. Paul Minnesota.  Freight prepaid and billed, subject to prior credit approval. 

 

MINIMUM ORDER:

 

$50.00 Net Price 

 

LOSS OR DAMAGE:

 

Loss or damage in transit is the responsibility of the carrier.  Any claim should be filed with 

the  delivering  transport  company.    Invoice,  Bill  of  Lading  and  Delivery  receipt  with  damage  noted  therein  must 

accompany  any  claims  for  freight  damage.    Claims  for  shortage  and  lost  shipments  must  be  made  in  writing  to 

Dimensions Unlimited, St. Paul, MN within 10 days of date of shipment.  Claims not reported within this time frame will 

not be honored. 

 

PRICES:

 

Prices are subject to change without notice.  All orders are subject to acceptance at the factory.  We reserve 

the right to invoice prices in effect at time of shipment. 

 

TERMS: 

Net 30 days with approved credit, credit card or C.O.D.

 

 

RETURN GOODS POLICY 

• 

No returned materials will be accepted without an accompanying Returned Materials Authorization Number (RMA) 

from factory. 

• 

Credit will be issued for returned goods to the original purchaser within 60 days of purchase, provided the inverter is 

returned  to  Dimensions  unused  and  not  mounted.    The  amount  of  credit  will  be  issued  at  Dimensions  discretion 

based on the condition of the product. 

• 

Customer must be in good standing with Dimensions Unlimited. 

• 

Inverters  that  are  discontinued,  high-voltage  (over  24vdc),  special-order  or  used  are  excluded  and  will  not  be 

eligible for credit.  Non-inverter items such as cable assemblies, fuses and fuse holders, will not be eligible for credit 

• 

Support components supplied by Dimensions vendors will be covered under that manufacturer’s credit return policy. 

• 

Customer pays return freight. 

 

PLEASE SHIP FREIGHT PREPAID AUTHORIZED RETURNS TO: 

Dimensions Unlimited, Inc. / 4467 White Bear Parkway / St. Paul, MN 55110 

 

LIMITED WARRANTY:

 Dimensions Unlimited warrants to the original purchaser for use that the goods or any 

component  thereof  manufactured  by  Dimensions  Unlimited  will  be  free  from  defects  in  workmanship  from  the  date  of 

purchase for the period listed on the product label, provided such goods are installed, maintained and used in accordance 

with Dimensions Unlimited and the original manufacturer’s written instructions. 

 

Components  not  manufactured  by  Dimensions  Unlimited,  but  used  within  the  assembly  provided  by  Dimensions,  are 

subject to the warranty period as specified by the individual manufacturer of said component, provided such goods are 

installed, maintained and used in accordance with Dimensions Unlimited and the manufacturer’s written instructions. 

 

Dimensions Unlimited sole liability and the Purchaser’s sole remedy for a failure of goods under this limited warranty and 

for any and all claims arising out of the purchase and use of the goods, shall be limited to the repair or replacement of 

the  goods  that  do  not  conform  to  this  warranty.  The  return  of  the  purchase  price  in  cash  is  at  the  sole  discretion  of 

Dimensions. 

 

To obtain repair or replacement service under the limited warranty, the purchaser must contact the factory for a Return 

Material Authorization (RMA).  Once obtained, send the Return Material Authorization Number along with the defective 

part or goods to: Dimensions Unlimited Inc., 4467 White Bear Parkway, St. Paul, MN 55110, freight prepaid. 

 

THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS OTHER THAN AS SET FORTH ABOVE.  THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE 

YEAR FROM DATE OF PURCHASE. 

 

DIMENSIONS  UNLIMITED  ASSUMES  NO  LIABILITY  IN  CONNECTION  WITH  THE  INSTALLATION  OR  USE  OF  THE 

PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY.  DIMENSIONS UNLIMITED WILL IN NO EVENT BE LIABLE 

FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 

 

WARNING: LIMITATIONS ON USE:

 Dimensions Unlimited products are not intended for use in connection 

with Life Support Systems and for Avionic use.  Dimensions Unlimited makes no warranty or representation in connection 

with their products for such uses.

  

 

 

Содержание 12X16B3R4T

Страница 1: ...d Company Dimensions Unlimited Inc DC to AC Standby Power Systems Owners Manual for Models 12X16B3R4T 12X20B3R4T 12X25B3R4T 12X30B3R4T 12X36B3R4T Including Options R1 LCD Remote Control Status Panel w...

Страница 2: ...llation 9 5 1 Tools Needed for Installation 9 5 2 System Components 9 5 3 Mounting the SPS 9 5 3 1 Chassis Bonding Lug 9 5 3 2 Temperature Compensation Sense Probe 9 5 3 3 Connecting the LCD Remote Co...

Страница 3: ...ounted in a location that may be exposed to rain or spray The Standby Power Systems should not be installed in a zero clearance enclosure Damage to the Standby Power Systems will occur if correct pola...

Страница 4: ...RELAY T Fail safe shore power Transfer Relay Current Rating Amps AC 30 Transfer Time milliseconds Less than 16 typical Output Voltage VAC 120 RMS 5 Output Frequency 60 Hz 0 05 Output Waveform Quasi si...

Страница 5: ...the transformer which steps the voltage up to 120 volts The unit has a Digital System Processor DSP to control the output voltage and frequency as the DC input voltage and or output load varies The s...

Страница 6: ...he plates of the battery cells The SPS has an automatic power sharing feature that automatically decreases the battery charger output so that the total AC input current draw by the SPS for both the AC...

Страница 7: ...put Output lead wires and DC field wiring compartment 3 Remote Control Panel Connector Connects to the LCD Remote Control Status Panel 4 Temperature Compensation Sensor Connector Connects to the remot...

Страница 8: ...ery charger 5 LCD Display Shows system status battery voltage and electrical current in both inverter and external power mode as well as shut down conditions 6 DC Master Disconnect switch control wire...

Страница 9: ...eing in the same airtight compartment If mounting the SPS on a vertical surface it is recommended that the front panel be pointing down whenever possible Locate the mounting holes on the chassis flang...

Страница 10: ...inches Heatsinks are available with the U option only or any 3600 watt inverter Front of the unit is to the right Heatsinks Figure 4 LCD Control panel footprint Assemblies 141255 2 or 141315 1 5 25 3...

Страница 11: ...model on table I cross reference the wire gauge and fuse size Table I Wire and Fusing Guide for 12VDC systems at 5 Voltage Drop at Full Output Figure 5 Inverter cable assembly 6 1 2 Charge Cable This...

Страница 12: ...f the battery bank a one time spark will occur when this final DC connection is made To determine the fuse size refer to section 6 1 1 6 1 3 Deep Cycle Batteries Do not use vehicle starting batteries...

Страница 13: ...recommended is Hubbell GFR 5352XX 20A or GFR 5252XX 15A Do not connect another source of AC power directly to the output of the SPS This will result in damage to the SPS that is not covered under warr...

Страница 14: ...put Under the hood Remote Temp Sense Red Black Charge Cable Red Connect the charging cables directly to the vehicle alternator whenever possible or to the OEM starting engine battery 2 pin Connector R...

Страница 15: ...tput Breaker AC Output AC Input 30A 20A Black wire Hot White wire Neutral Green wire Ground Black White Green Wire Wire Wire Hot Neutral Ground Install GFCI outlets Hubbell GFR 5352XX 20A or Hubbell G...

Страница 16: ...NDITIONING max BULK max ACCEPT max CONDITIONING max Less than 400 6 hrs 2 hrs 3 hrs 6 hrs 2 hrs 3 hrs Greater than 400 8 hrs 3 hrs 6 hrs 8 hrs 3 hrs 4 hrs If the bulk mode times out the charging proce...

Страница 17: ...the SPS The inverter is also turned OFF c When external AC power is connected to the SPS the three stage battery charger may be activated This indicates that the charge current limit has been set to 0...

Страница 18: ...n while the inverter is OFF and there is no external power connected to the SPS Pressing this button again will turn the inverter ON and message a will appear j This message is displayed when you pres...

Страница 19: ...troubleshooting table 7 2 1 Troubleshooting Chart MESSAGE PROBLEM POSSIBLE CAUSE 1 The SPS is not connected to the batteries or the battery voltage is below 9 volts DC Check the in line fuses for con...

Страница 20: ...battery Make sure that the DC cable connections are tight and clean and not shorted and that the proper wire gauge is used 9 Indicates that the charger has shut off due to high battery temperature 47...

Страница 21: ...verter On INVERTER xx xx WATT BATT xx x VOLTs CHGR OFF NO INPT INVERTER OFF Start battery charger Pass AC to loads No Yes No Yes No Yes Is current limit set at 0 amp CHGR OFF 0 AMP LIMIT SET Start bul...

Страница 22: ...D MODE xx x VOLT xxx AMP Has condition timer finished Stay in voltage conditioning Yes No Yes No Stay in acceptance mode CHGR ACCEPT MODE xx x VOLT xxx AMP No Yes Continued from previous page Has acce...

Страница 23: ...se that the goods or any component thereof manufactured by Dimensions Unlimited will be free from defects in workmanship from the date of purchase for the period listed on the product label provided s...

Страница 24: ...appliances and components found on RVs was something that I always had a desire to create I hope this resource makes your RV repairs easier as it has mine but please be careful and follow proper safe...

Отзывы: