8
Auto configuration (recommended)
The default chunk size is
64k
when selecting
Auto configuration
.
1. As the BIOS boots press
Ctrl+S
or
F4
when prompted to enter
the RAID BIOS.
2. At the next screen select
Create RAID Set
, then press
Enter
.
3. Select
RAID10
, then press
Enter
.
4. Select
Auto configuration
, then press
Enter
.
5. Input the RAID size, press
Enter
.
6. When
asked
Are You Sure(Y/N)?
, press
Y
to accept.
7. Press
Ctrl+E
to exit the BIOS.
8. When
asked
Are you sure to exit(Y/N)?
,
press
Y
to exit and reboot.
9. Continue with FDISK and FORMAT steps as
if you were installing a conventional hard drive.
Manual configuration
1. As the BIOS boots press
Ctrl+S
or
F4
when prompted to enter the RAID BIOS.
2. At the next screen select
Create RAID Set
, then press
Enter
.
3. Select
RAID10
, then press
Enter
.
4. Select the number of drives then press
Enter
.
5. Select
Manual configuration
then press
Enter
.
6. Select chunk size from
8k, 16k, 32k, 64
or
128k
, then press
Enter
.
7. Select
the
first drive
, press
Enter
.
8. Select
the
second drive
, press
Enter
.
9. Select
the
third drive
, press
Enter
.
10. Select the
fourth drive
, press
Enter
.
11. Select
Create without data copy
then press
Enter
.
12. Input the RAID size, press
Enter
.
13. When asked
Are You Sure(Y/N)?
, press
Y
to accept.