RD-SR2 

 

Proximity Card Reader   

with Remote Control 

 
 

 

 

 
 
 
User Manual 

ACCESS 

SECURITY 

PRODUCTS 

LTD

Summary of Contents for RD-SR2

Page 1: ...RD SR2 Proximity Card Reader with Remote Control User Manual A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 2: ...ogrammable relay operation Pulse mode Latch mode relay operation Remote infrared programmer Master Add Master Delete cards 1000 users 998 common users 2 panic users User data can be transferred from one unit to another Wiegand 26 37 bit input output Card block enrolment Tri colour LED status display Built in light dependent resistor LDR for anti tamper Buzzer for audible or silent mode Low tempera...

Page 3: ... Contents SR2 Card Reader Infrared Remote Control Manager Cards Diode IN4004 For relay circuit protection Self Tapping Screws 3 25mm Wall Anchors Screw Driver A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 4: ...ing cable Wire Insulation Colour Function Notes Red Power AC1 12 24 Volts AC DC Power input Black GND Ground Pink AC2 12 24 Volts AC power input Blue NO Normally open relay output Purple COM Common connection for relay output Orange NC Normally closed relay output Yellow OPEN Request to exit input REX Green Data 0 Wiegand output Data 0 White Data 1 Wiegand output Data 1 Grey Alarm output Negative ...

Page 5: ...cure power to unlock Common power supply for auto gate controller using Normally Open contact Attention Install a 1N4004 or equivalent diode across the locking device when using a common power supply to prevent any back E M F as the reader might damage 1N4004 is included in the packing A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 6: ...ory default for stand alone 73 4 Exit Program Mode User data transfer connection 1 x power supply and 9 x SR2 units Set User Data Transfer Programming Step Remote Control Operation 1 Enter Program Mode 2 Set Transfer Data on the first SR2 For all 1000 users this will take 3 minutes Master Code 96 Within 3 minutes the green LED will shine after 1 x bleep the LED will turn red to confirm data transf...

Page 7: ...d by Red light bright Enter into programming mode Red light shines One bleep In the programming mode Orange light bright One bleep Operation error Three bleeps Exit from the programming mode Red light bright One bleep Open lock Green light bright One bleep Alarm Red light Shines quickly Bleeps Please see Reset Procedure for ALARM Enter and Exit Program Mode Via the Remote Control Set New Master Co...

Page 8: ... in a single step this takes 2 minutes 1 Present Card Repeat Step 2 for additional user cards 1 User ID Present Card The user ID is any number from 0 997 1 Input the 8 10 digit Card number 1 User ID Card Quantity The first card number Card or fob number MUST be consecutive 6 Exit Program Mode Add PIN User For Administrator for Remote Control Programming Step Remote Control Operation 1 Enter Progra...

Page 9: ...r 10 failed card attempts Default setting is OFF The strike out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after presenting a valid user card or Master code Programming Step Remote Control Operation 1 Enter Program Mode 2 Strike Out OFF OR 3 Strike Out ON OR 4 Strike Out ON Alarm Set alarm time Master Code 6 0 factory default 6 1 Access will be...

Page 10: ...default power off press the Exit Button or short circuit the Black GND and Yellow Open wires and then power on there will be two bleeps and the LED light will turn orange keep this condition until you hear a long bleep after 10 seconds The LED will turn red to confirm factory default is successful Reset to Factory Default to add new Mater Cards To reset to factory default power off press the Exit ...