6.4.8.2. Programming additional cams on an output
Task:
A cam shall be programmed in program 0, on output 2 from 300 to 330 in addition to an already
existing cam, e.g. from 100 to 200.
Solution:
1.
Press the
key (for about 2 sec.), until you enter the 'Program selection' mode:
.
2.
Press the
key (for about 2 sec.), you enter the 'Output selection' mode
.
3.
Press the
key to select output 2,
. The display also shows the begin of the
already programmed cam.
4.
Press the
key, you enter the 'Cam search' mode
.
5.
Press the
key for the input of the preselection
.
6.
Press the
key and keep it pressed until
appears on the display.
7.
If you have released the
key too early or too late, you can adjust the preselection to 300 with
the
or the
key.
8.
Press the
key, the activation point is displayed.
9.
Press the
key to program the deactivation point.
10. Press the
key and keep it pressed until
is displayed.
CAUTION!
Do not keep the key pressed too long. It is best to keep the
key pressed until 320
and then adjust to 330 step by step.
11. Press the
key. You return to the standard display.
NOTE:
When programming the activation and the deactivation points you are programming "on line", i.e. if you
keep the
key pressed for too long, the cam will be programmed too long. Although you can correct
this subsequently with the
key, the range between the desired end of the cam and cams entered in
excess is erased. All cams already programmed in this range are lost.
Version from: 18.06.2009