background image

MOUNTING 

4-6 mm 

Útjeladó 

Csavarfej 

MOUNTING

 

MONITOR  

Place the monitor on a clearly visible place in the tractor cabine and fix it with 
the  U-bracket  and  bolts,  up  or  bottom  position  to  avoid  direct  sunlight  on 
LCD.  The  display  is  illuminated  which  enables  nighttime  use  with  superb 
visibility 

 

The  monitor  is  connected  optimally  after  a  fuse  (max.  3A)  on  12  VDC, 
taking care of the right polarity.  

 

Connect the extension cable of moduls to the monitor.  

 

Do  not  connect  in  line  with  other  disturbing  signal  emitter 
devices.  

 

Welding works are allowed only when both power cables of 
the  monitor  are  disconnected  from  the  tractor’s  electronic 
system. 

SPEED SENSOR FOR HECTARE COUNT 

Mount speed sensor in front of a non-slipping wheel. 
The best is a freewheel which sized to give at lest 1 
signal in a distance traveled between 0,2 – 0,99 m. 
The  speed  sensor  gives  you  information  about  the 
distance traveled.  

Speed  sensors  are  inductive  sensors,  in  proximity  of  an  iron  part  e.g.  bolt 
heads  give  a  signal.  If  distance  between  sensing  bolt  heads  would  be  more 
than  1  meter,  additional  bolt  signallers  has  to  be  mounted.  This  way,  during 
calibration the distance traveled in 100 bolt signals remains under 100 meters. 

 
 
 
 
 
 
 

Checking operation: 

 

red LED at the end of speed sensor 

 

a symbol of speed sensor is blinking on monitor front 

 

 Important

: when planning the placement of speed sensor regard the risk 

Very important to adjust speed 
sensor within the sensing distance, 
generally between 4-6 mm from bolt 
head.

 

Содержание SEED MASTER Plus 8.6 Series

Страница 1: ...MANUAL DIGITROLL Ltd Tel 36 52 557 480 Web www digitroll hu Fax 36 52 557 482 Email info digitroll hu 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 1112 1314 15 16 SENSORS ALL IN ONE IN TELL IGEN T S EN S O R...

Страница 2: ...AR II DSI 18J RAD HIR 4 5m 2m 6m DA 02 SPEED MODUL 12VDC 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 10 11 1213 14 15 16 SENSORS ALL IN ONE IN TELL IGEN T S EN S O R TE C HN OL OGY STOP DISPLAY TEST INFO A B C...

Страница 3: ...G 6 MONITOR FRONT 7 SWITCH ON 7 SYSTEM TEST 8 MENU 9 SETTING BASIC DATA 10 MONITOR SETTINGS 13 CONTROL OF SEEDER SETTINGS 14 SEEDING CONTROL 16 STORED SEEDING DATA 19 DISTANCE MEASUREMENT 20 TROUBLESH...

Страница 4: ...display CONTROL OF SEEDER SETTINGS Statistics of 100 expected seeded grains Average seeded grains Population ratio control SEEDING CONTROL Simultaneously detected seeding continuity on all rows Selec...

Страница 5: ...tosensor Skipped row Oo Small large grains for DS 2000 photosensors J Bar diagram for population ratio control M Total area L Partial area RS Horn volume TU Tractor The seeding control system and its...

Страница 6: ...PEED SENSOR FOR HECTARE COUNT Mount speed sensor in front of a non slipping wheel The best is a freewheel which sized to give at lest 1 signal in a distance traveled between 0 2 0 99 m The speed senso...

Страница 7: ...1112 1314 15 16 SENSORS ALL IN ONE IN TELL IGEN T S EN S O R TE CH N OLO GY STOP DISPLAY TEST INFO A B C D 100 150 50 0 OUT A B C D 1 L R max STOP DIGITROLL 8 6 0 0 0 h a wheel LED display hold system...

Страница 8: ...k Sends data to adjustable modules DS2000 Having the test finished the found modules are presented on display After photosensor test the seed blockage control screen appears After simply switch on the...

Страница 9: ...al or Hybrid SETTING MIN AND MAX LIMITS FOR POPULATION CONTROL SELECTION OF SEED SEED SIZE SHAPE ENTRY OF DISTANCE TRAVELED IN 100 SPEED SIGNALS 100 SPEED SIGNAL COUNT SETTING DISPLAY LANGUAGE SELECTI...

Страница 10: ...value can be set directly after switch on too SETTING MIN AND MAX LIMITS FOR POPULATION CONTROL c Maximum limit alarms when population get over set value d Minimum limit alarms when population get und...

Страница 11: ...in that row After system test all connected sensors are displayed regardless of being switched on or off However skipped rows are not involved in seeding control and are indicated by a character SEEDI...

Страница 12: ...inductive sensor which detects bolt heads of a driven wheel In case of individual installation the number of signalling bolt heads must be enough to provide at least one signal at every 30 60 cms dis...

Страница 13: ...sensor adjustment has vital importance it should signal at the proximity of each bolt head LED indicates it by blinking both on the sensor and the monitor SETTING OF DISTANCE TRAVELED IN 100 SPEED SEN...

Страница 14: ...easured seeds number of double seed drops O number of missing seeds Holding the constant speed precisely is a condition of exact masuring The data of the next row is visible after each measuring cycle...

Страница 15: ...ource total seed count can help Total seeds are around 100 inhomogeneous seed spacing improper seed separation hindered seed drop etc Total seeds are less than 100 seeds cannot be picked up from seed...

Страница 16: ...s recommended when Small less than 5 mm diameter hardly detectable seeds are sown Necessary basic data are not entered in the monitor Speed sensor is damaged Sensor performance wanted to check at stop...

Страница 17: ...ed ha value displayed here with the total area seed ha which is shown by pushing the INFO button See also STORED SEEDING DATA Alarm The monitor alarms you when difference goes beyond min or max limit...

Страница 18: ...JJJJJBJJ Push button again to return seeding control mode J JDJ At landmarks when every row stop seeding the console stores seeding data and according to preset limit time displays missing seeds and s...

Страница 19: ...yed You have the option to measure Total accumulated and Partial area Partial area counts and seeded grains are added to the totals and can be cancelled together or separated In both cases area can be...

Страница 20: ...al is used here Measurement begins when START button pushed appears new display on screen and it ends by the next push of the button Deletion of measured distance push button lastingly for approx 2 se...

Страница 21: ...when overloaded Signs LED lights normal function LED blinks partial overload LED off total external short circuit Probe Disconnect modules from monitor If LED lights after a short pause external short...

Страница 22: ...is defected between modules 4 and 5 output side of module 4 or the module 5 is defected b LED lights at modules5 6 etc Power supply is in order communication cables are hurt between modules 4 and 5 or...

Страница 23: ...ED DROPS WHEN SEEDER STOPPED Seeds or seed fragments picked up accidentally by the air flow are detected by the seed sensor Sensitivity was set too high adjust higher time limit to reduce sensitivity...

Страница 24: ...monitor to direct water do not store it under 20 C and above 40 C temperature protect it from excessive heat and dust Remove the monitor from the cabine for winter and store at a dry vapourfree place...