1.
Disable HAG
2.
Enable HAG
3.
Set HAG
HAG Menu
3. If the HAG value shown at the bottom of the screen is acceptable, select
Enable HAG
. The
receiver beeps four times as it enables HAG and returns to the Main menu. Skip the next step.
4. To change the HAG value shown at the bottom of the screen, select
Set
HAG
and enter a new value. After you select
Enter
on that screen, the
receiver beeps four times as it enables HAG and returns to the Main
menu.
Page 11
Depth readings (holding the trigger) must now be taken with the receiver held at this height.
As noted above, to prevent incorrect readings, HAG must be turned on manually each time after the receiver
is powered on or calibrated.
I use HAG all the time; can I set it to turn on automatically?
No. In the name of safety, HAG must be turned on manually for each use. However, the feature
does remember the last height value used.