DigiTrak Falcon F5® Operator's Manual
15
4. At the Main menu, select
Calibration
and then
1 pt calibration
.
1.
1 pt calibration
2.
In-Ground Calibration
3.
View Calibration
4.
Above Ground Range (AGR)
Calibration Menu
5. Use a tape measure to ensure the distance from the center of the transmitter to the inside edge of
the receiver is 3 m as shown below, then click
Continue
to begin the calibration.
6. Do not move the receiver. A successful calibration yields a check mark
and four beeps.
Calibration can fail for one of three reasons:
Transmitter signal is
too low (below 300
points)
Transmitter signal is
too high (above 950
points)
Extreme signal
attenuation is in effect
If calibration fails, review the items mentioned in the question titled
Why do I keep getting calibration
errors?
below, read more about signal attenuation in
(if it applies), then click
Retry
to try
calibrating again.