OPERATING INSTRUCTIONS MODEL 

XR500/XR500N PANELS

NORMAL STANDBY CONDITION

When the system is in the normal standby condition, the keypad shows either 
the time of day or a blank display.

ALARM CONDITION

When the system is in an alarm condition, the keypad display shows the 
violated zone name(s) followed by an alarm display.

ALARM SILENCE

To silence the alarm while the bell or siren is sounding, enter your code 
number and press the COMMAND key. This silences the alarm but does 

not

 

cancel any alarm reports to the central station.

RESETTING DETECTORS

To reset a smoke or other detector, enter the User Menu by pressing the 
COMMAND key until 

MENU?  NO  YES

 appears in the display. Press the top row 

key under 

YES

. The display shows 

ENTER CODE: -

.  Enter your code number 

and press COMMAND. The keypad display now shows 

ALARM SILENCE? 

if your 

code allows. Press the COMMAND key until 

SENSOR  RESET?

 appears in the 

display. Press any top row key.

TROUBLE CONDITION

When a device is in a trouble condition, the keypad tones and displays the 
zone or device name followed by 

TRBL

. Press any top row key to silence.

SYSTEM TESTING

You should test the security system periodically to ensure proper operation. 
You can do this through a

 

function in the User Menu. After entering the User 

Menu, press the COMMAND key until 

SYSTEM TEST? 

displays. Press the left 

most top row Select key. The system bell, battery, and communication to the 
central station receiver system is then tested.

ALARM SERVICE

If service is required for this system, please contact:

Company_____________________________________________

Address ______________________________________________

Telephone ____________________________________________

The operating instructions above should be attached to the front, or framed and located 

adjacent to, the panel or a Security Command keypad with an alphanumeric display.

Содержание COMMAND PROCESSOR XR500

Страница 1: ...INST ALLA TION GUIDE XR500 XR500N ACCESS CONTROL COMMAND PROCESSOR PANEL LT 0681 1 04 2004 Digital Monitoring Products Inc...

Страница 2: ...the installer is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the compu...

Страница 3: ...4 1 Mounting the Enclosure 7 4 2 Mounting Keypads and Zone Expansion Modules 7 4 3 Connecting LX Bus and Keypad Bus Devices 8 Primary Power Supply 5 1 AC Terminals 1 and 2 8 5 2 Transformer Types 8 Se...

Страница 4: ...Expansion Connector 15 1 Description 16 15 2 J22 LX Bus Header 16 15 3 LX Bus Interface Cards 16 15 4 LX Bus LEDs 17 15 5 OVC LED 17 J21 Serial Connector 16 1 Description 17 16 2 Serial Connector LED...

Страница 5: ...2 23 6 Grade B Central Station 22 23 7 Bell Cutoff 22 23 8 AA Network Communication 22 UL 1635 Speci cations 24 1 System Trouble Display 22 24 2 Digital Dialer Telephone Number 22 24 3 Test Time 22 24...

Страница 6: ...29 5 Local Protective Signaling Systems 26 29 6 Remote Station Protective Signaling Systems 26 29 7 Fire Protective Signaling Systems using Internet Intranet Networks 26 UL 985 NFPA 72 Chapter 2 Speci...

Страница 7: ...reset zones 9 and 10 1 4 Keypad Bus You can connect up to 16 of the following supervised keypads and expansion modules to the keypad bus Alphanumeric keypads Four and or single zone expansion modules...

Страница 8: ...X Bus Expansion Keypad Expansion Bus 711 Zone Expander 711 Zone Expander Door Contact Window Contact Strobe Roll Up Doors 791 793 Security Command Keypad Proximity Reader 5845LX Glassbreak Detector Si...

Страница 9: ...uch as UL The System Diagrams illustrate different ways to wire the XR500 XR500N to a variety of modules Caution Notes Throughout this guide you will see caution notes containing information you need...

Страница 10: ...ector Use UL Listed Power Supervision Relay rated at 12 VDC 1k Ohm s Supervised Circuit Zone 9 Zone 10 22 gauge minimum 22 gauge minimum 22 gauge minimum 22 gauge minimum RED YELLOW GREEN BLACK 1k Ohm...

Страница 11: ...equires 710F Bus Splitter Repeater 716 Output Expander Provides four Form C relays SPDT and four switched grounds open collector for use in a variety of remote annunciation and control applications 71...

Страница 12: ...m DMP Part Number Description Wheelock Model No 12V 801 Mini Horn MIZ 12 x 802 Multi tone Horn MT 12 24 x 803 Standard Horn NH 12 24 x 806 6 Bell 6 inch MB G6 12 x 806 10 Bell 10 inch MB G10 12 x 821...

Страница 13: ...e J10 J22 LX Bus Battery Start J23 J21 RS 232 Power LED J8 PROG J4 Tamper J16 Reset Out1 Out2 Outputs 3 6 J11 3 4 5 6 J2 J1 Ethernet R L X OVC Power LED Link LED Figure 3 XR500 XR500N in Model 350A En...

Страница 14: ...increases DC voltage on the wire decreases Maximum number of LX Bus devices per 2 500 feet circuit is 40 For additional information refer to the 710 Installation Sheet LT 0310 and or the LX Bus Keypad...

Страница 15: ...cutoff relay is pulled in automatically For more information refer to Figure 2 6 4 Battery Replacement Period DMP recommends replacing the battery every 3 to 5 years under normal use 6 5 Discharge Re...

Страница 16: ...Qty ______x Qty ______x Qty ______x 30mA 2mA 20mA ______ ______ ______ 736P POPIT Interface Module Radionics Popex POPITs OctoPOPITs Qty ______x Qty ______x 25mA ___mA ______ ______ Qty ______x Qty _...

Страница 17: ...stalled to the left of the XR500 XR500N enclosure to ensure Battery and AC wire separation 24 hours of standby power 4 5 Ah Batteries 7 Ah Batteries 7 7 Ah Batteries 9 Ah Batteries 18 Ah Batteries Max...

Страница 18: ...Terminal 8 receives data from keypads and zone expansion modules It cannot be used for any other purpose 8 4 Terminal 9 GREEN Terminal 9 transmits data to keypads and zone expansion modules It cannot...

Страница 19: ...esistance on zone Voltage on positive terminal Open over 1300 ohms over 2 0 VDC Normal 600 to 1300 ohms 1 2 to 2 0 VDC Short under 600 ohms under 1 2 VDC 10 3 Zone Response Time A condition must be pr...

Страница 20: ...725 Hochiki SIJ 24 HD 3 NS6 220 HB 3 15 33 20 725 Hochiki DCD 190 DCD 135 HD 3 NS6 220 HB 3 15 33 16 725 Sentrol ESL 429AT 521B 521BXT 521NB 521NBXT S09A 6 5 20 12 715 715 8 715 16 9 10 Sentrol ESL 42...

Страница 21: ...Color Output 1 normally closed Violet Output 1 common Gray Output 1 normally open Orange Output 2 normally closed Violet with white stripe Output 2 common White with gray stripe Output 2 normally ope...

Страница 22: ...hen using J22 as an LX Bus connect a DMP Model 300 4 wire Harness to the J22 4 pin header labeled LX BUS This provides the rst 100 LX Bus zones numbered 500 599 No LX Bus Interface Card is required Re...

Страница 23: ...onnector indicate network operation The top Activity LED flashes green to indicate the network traffic is good The bottom Link LED flashes yellow to indicate messages are being sent and received J3 Te...

Страница 24: ...to the 893A Installation Sheet LT 0135 for complete information 18 4 Noti cation The user must not repair registered terminal equipment In case of trouble immediately unplug the device from the teleph...

Страница 25: ...place the Reset jumper over both of the J16 pins to reset the panel AC 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 9 20 21 22 23 24 25 26 27 28 B BELLGND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7...

Страница 26: ...station phone number 20 5 Bypass Reports The Bypass Reports option must be programmed as YES for all UL burglary applications See the XR500 XR500N Programming Guide LT 0679 20 6 System Maintenance To...

Страница 27: ...l be able to disarm that area UL 1023 Speci cations Household Burglar Alarm System Units 22 1 Audible Devices At least one listed audible device Ademco AB12M rated to operate over the voltage rate of...

Страница 28: ...e installed in a UL AA application when NET communication is used The NET network check in time must be set from 01 to 06 minutes or AA This provides AA Central Station service When a dialer is requir...

Страница 29: ...annot be less than 15 minutes See the XR500 XR500N Programming Guide LT 0679 25 6 Automatic Bell Test The Automatic Bell Test option must be programmed as YES See the XR500 XR500N Programming Guide LT...

Страница 30: ...used 26 5 Grade A Bell A Grade A local audible signal appliance must be used such as Ademco AB12M bell and bell housing 26 6 Bank Safe and Vault XR500N only In addition to the requirements for Mercan...

Страница 31: ...hone number unless that phone number is speci cally provided for that purpose 28 8 System Maintenance To ensure continuous satisfactory operation of any alarm system proper installation and regular ma...

Страница 32: ...ours See the XR500 XR500N Programming Guide LT 0679 29 5 Local Protective Signaling Systems The DMP Model 865 866 or 867 Noti cation Circuit Module must be used on the bell circuit for detection of sh...

Страница 33: ...d rated at 85 DB minimum must be used 30 3 Auxiliary Circuits At least one re alarm initiating device shall be used on the system If the voltage for the device is applied by the control unit the re al...

Страница 34: ...to a maximum of twenty five 866 Modules on the XR500 XR500N panel All modules must be installed in a 340FC 349 or 350 enclosure connected by no more than 20 feet of conduit S 24 VDC 5 Amp Maximum Pow...

Страница 35: ...es Install up to a maximum of twenty five 866 Modules by using the relay outputs available on the XR500 panel All modules must be installed in a 340FC 349 or 350 Enclosure connected by no more than 20...

Страница 36: ...GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start J23 J21 RS 232 J8 J4 Tamper J16 Reset J11 J2 J1 GND Fault A GND Fault B A1 A1 A2 A2 Zone A...

Страница 37: ...ttery Start J23 J21 J8 PROG J4 Tamper J16 Reset J11 J2 J1 Cellular Transceiver Supervised Circuit S 1 2 3 4 5 6 Panel Auxiliary Power Terminal 7 Note 1 Note 1 Telco Jack Panel Common Terminal 10 Super...

Страница 38: ...1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 9 20 21 22 23 24 25 26 27 28 B BELL GND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start...

Страница 39: ...itional LX Bus Modules Red Yellow Green Black LX Bus Wiring TENS ONES TENS ONES Bell Relay Address Supervisory Address Each LX Bus Module must have its own independent address ranging from 00 to 99 A...

Страница 40: ...B BELL GND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start J23 J21 RS 232 J4 Tamper J16 Reset J11 J2 J1 R L X 12 VDC Relay 4 Relay 3 R...

Страница 41: ...XR500 XR500N Installation Guide Digital Monitoring Products 35...

Страница 42: ...CODE Enter your code number and press COMMAND The keypad display now shows ALARM SILENCE if your code allows Press the COMMAND key until SENSOR RESET appears in the display Press any top row key TROU...

Отзывы: