Self-Test Error Messages,
Continued
Extended Error Format 10:
This format is used by the DSW21 communications device when it
first executes code, and is used to verify that the 68K is executing
instructions.
020 000A 00040003 00060005 00080007 00100009 00120011 00140013
00160015
Format
Meaning
020
The FRU for the DSW21 communications
device
000A
Format type
DSW21
Communications
Utilities Error
Codes
Table A–22 lists the DSW21 utilities error codes.
Table A–22 DSW21 Communications Utilities Error Codes
224
E0
Invalid utility request
226
E2
Invalid test request
255
FF
Control C entered
Continued on next page