Self-Test Error Messages,
Continued
OBIT
Table A–6 lists the OBIT self-test decimal and hexadecimal error
codes.
Table A–6 OBIT Self-Test error codes
Decimal
Hexadecimal Meaning
6
6
Failed floating 1s and 0s data test
8
8
Failed verify background pattern =
AAAAAA, write 555555
10
A
Failed verify second pattern = 555555,
write 0
12
C
Failed verify background pattern = 0,
then write FFFFFF
14
E
Failed verify second pattern =
FFFFFF, write 0 and good ECC
Continued on next page