Interfaces

      Analog RGB Interface

8

7

6

5

4

3

2

1

ON

  

  SW1

SW1-8 Reserved (Set this switch to OFF)

SW1-7 Reserved (Set this switch to OFF)

SW1-6 Reserved (Set this switch to OFF)

SW1-5 Switch between analog RGB and DVI-D input

SW1-4 Reserved (Set this switch to OFF)

SW1-3 Reserved (Set this switch to OFF)

SW1-2 Display/hide the OSD

SW1-1 Switch between USB and RS232C for touch panel data

transmission.

• SW1-1

Dip Switch SW1-1 is used to set the touch panel data input (command
control) method to either USB or RS-232C.

When the switch is set to OFF, data output and command input/output are
performed via RS-232C. When the switch is set to ON, USB is used.

The default setting is OFF. (RS-232C)

• SW1-2

Dip Switch SW1-2 is used to display or hide the OSD.

To hide the OSD, set the switch to ON. To display the OSD, set the switch
to OFF.

The default setting is OFF. (OSD is displayed.)

• SW1-5

Dip Switch SW1-5 is used to change the image input method.

When the switch is set to ON, DVI-D image input method is used. When the
switch is set to OFF, the analog RGB image input method is used.

The default setting is OFF. (Analog RGB is used.)

Input signal type

Analog RGB

Input signal characteristic Image signal: analog RGB

Synchronous signal: T T L level, negative true or positive true

Scanning type: non-interlace

Setting by OSD

 (On Screen Display)

CONT RAST

BLACK LEVEL

H-POS

V-POS

OSD H-POSIT ION

PHASE

BACKLIGHT

DEFAULT  (ALL CLEAR)

Содержание Pro-face FP3700-T41

Страница 1: ...hes the panel a potentially dangerous machine miss operation can occur Therefore do not use FP touch switches for the con trol of any equipment safety mechanisms such as Emergency Stop switches etc that protect humans and equipment from injury and damage If your FP s backlight suddenly turns OFF use the following steps to deter mine if the backlight is actually burned out 1 If your currentFP appli...

Страница 2: ...the FP in an area containing chemicals or chemical fumes Do not use paint thinner or organic solvents to clean the FP unit s case or screen After turning the FP OFF be sure to wait a few seconds before turning it ON again If the FP is started too soon it may not start up correctly UL c UL CSA ApplicationNotes CE Marking Notes The FP3700 T41 is a UL c UL CSA listed product UL File No E220851 This u...

Страница 3: ...B interface F DVI D Interface Connector Connector for DVI D interface G RS 232C Connector Connector for RS 232C serial interface Used for sending touch panel data to the host and for receiv ing commands from the host H USB Connector Connector for USB interface Used for both send ing touch panel data to the host and receiving commands from the host I Front LED Used to indicate the condition of the ...

Страница 4: ...r the cover shown below Rear view After changing your FP unit s Dip Switch settings please reboot your FP 2 Dimensions Unit mm in Dip swiches Front View 383 15 08 294 11 57 282 11 1 395 15 55 60 2 36 Top View 5 0 2 Side View 34 9 1 37 44 1 73 ...

Страница 5: ... RS 232C When the switch is set to ON USB is used The default setting is OFF RS 232C SW1 2 Dip Switch SW1 2 is used to display or hide the OSD To hide the OSD set the switch to ON To display the OSD set the switch to OFF The default setting is OFF OSD is displayed SW1 5 Dip Switch SW1 5 is used to change the image input method When the switch is set to ON DVI D image input method is used When the ...

Страница 6: ... Vertical Display Resolution 640 400 24 827 56 000 21 053 640 400 31 469 70 000 25 175 640 480 31 469 59 992 25 175 640 480 37 500 75 000 31 500 640 480 35 000 66 667 30 240 720 400 1 31 469 70 000 28 320 1 42 H 1 92 V 1023 767 800 600 37 879 60 317 40 000 800 600 46 875 75 000 49 500 1024 768 48 363 60 004 65 000 1024 768 56 476 70 069 75 000 1024 768 60 023 75 029 78 750 1 6 H 1 92 V 1024 767 1 ...

Страница 7: ... 24 pin male Connector set screw Inch type 4 40 Cable DVI D cable manufactured by Digital Electronics Corporation of Japan FP DV01 50 5 m FP DV01 100 10 m The FP DV01 100 can be used only when connected to a PS 2000B unit When using the FP DV01 100 be sure to turn the PS 2000B s internal dipswitch 4 ON When using the FP DV01 50 turn this switch OFF If a cable other than the specified DVI D cable i...

Страница 8: ...ld be connected to the RD input terminal on the PC s connector Refer to the FP3700 T41 User Manual s section 2 4 Cable Diagrams for each signal s direction If a cable other than the specified RS 232C cable is used product per formance cannot be guaranteed due to the possibility of noise interfer ing with the FP unit s operation Communication Low speed Device Connector B type connector Cable USB ca...

Страница 9: ... of the unit s cor ners only in the straight sections of the groove Inserting it into a corner may lead to its eventually tearing To ensure the installation gasket s maximum level of moisture resis tance be sure the gasket s seam is inserted as shown into the panel s bottom face Confirm the Installation Gasket s Positioning It is strongly recommended that you use the gasket It absorbs vibration in...

Страница 10: ...st screen image display to a minute level The feature is called OSD On Screen Dis play For details FP3700 T41 User Manual 3 3 3 Calibration of OSD Display Position Tightening the screws with too much force can damage the FP unit s case The necessary torque is 0 5N m To avoid an electric shock when connecting the FP s power cord terminals to the power terminal block confirm that the FP s power supp...

Страница 11: ...and remove the AC Power Cord from the Cord Clamp Figure 2 Cord Clamp Lock Pin Lock Pin Hole Lock Tab Release Cord Clamp AC Plug Collar AC Plug AC Connector 8 Using the USB Cable Strap USB Cable Strap Attachment Procedure 1 Connect the USB cable to the connector 2 Insert the cable strap into the cable strap holder as shown in figure 1 and tighten the strap until the cable is secured in place USB Ca...

Страница 12: ...ww pro face com 2003 Digital Electronics Corp FP Model No Backlight Model FP3700 T41 CA3 BLU15 01 Please pay special attention to the following instructions when connecting the power cord terminals to the FP unit If the power supply voltage exceeds the FP unit s specified range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is still a...

Отзывы: