Panel thickness
1.6mm[0.06in] to
10mm[0.39in]
FP
Panel
Attach the Installation Fasteners from Inside the Panel
The following figures show the eight(8) fastener insertion slot locations. Insert each
fastener's hook into the slot and tighten it with a screwdriver.
• Before installing the FP into a cabinet or panel, check that the installation
gasket is securely attached to the unit.
• A gasket which has been used for a long period of time may have
scratches or dirt on it, and could have lost much of its dust and drip
resistance. Be sure to change the gasket periodically or when
scratches or dirt become visible.
• Be sure to use gasket model CA3-WPG15-01.
• Be sure the gasket's seam is not inserted into any of the unit's cor-
ners, only in the straight sections of the groove. Inserting it into a
corner may lead to its eventually tearing.
• To ensure the installation gasket's maximum level of moisture resis-
tance, be sure the gasket's seam is inserted as shown into the panel's
bottom face.
Confirm the Installation Gasket's Positioning
It is strongly recommended that you use the gasket. It absorbs vibration in addition to
repelling water.
Place the FP on a level surface with the display panel facing downward. Check that the
FP’s installation gasket is seated securely into the gasket’s groove, which runs around the
perimeter of the panel’s frame.
Gasket
Rear face
5
Installation
Unit: mm [in]
Create a Panel Cut and insert the FP into the panel from the front
Panel
383.5 [15.1 ]
+1
0
+0.04
0
282.5
[1
1.12 ]
+0.04
0
+1
0
under 4-R3
FRONT
FP
Panel
FP
Installation
fastener
Insertion Slots
Top
Bottom
Left side