POST and Boot Messages
(continued)
Message
Description/Solution
nnnn Cache SRAM Passed
Where nnnn is the amount of server cache (in kilobytes) that tested
successfully.
Diskette drive A error
Diskette drive B error
Run the SCU. Check all connections. If the problem persists-replace the
diskette drive.
Entering SETUP
SCU runs.
Extended RAM Failed at offset:
nnnn
Extended memory failed or configured incorrectly.
Make sure SIMMs are installed correctly. If the problem persists replace
the defective RAM.
Run the BIOS Setup utility and restore all settings to original values.
nnnn Extended RAM Passed
Where nnnn is the amount of extended memory (in kilobytes) that tested
successfully.
Failing Bits: nnnn
nnnn is a map of the bits at the RAM address which failed the memory
test. Run the SCU and restore all settings to original values.
Fixed Disk 1 Failure
Fixed Disk Controller failure
Run the SCU. Check all connections. If the problem persists contact
your Digital SERVIC REPRESENTATIVE.
Incorrect Drive A type - run
SETUP
Incorrect Drive B type - run
SETUP
Diskette drive A and/or B not correctly identified in the BIOS Setup
utility.
Run the SCU and properly identify diskette drive A and/or B.
Invalid NVRAM media type
NVRAM access failed.
Run the SCU and restore all settings to original values.
If the problem persists replace the defective component.
Keyboard controller error
Keyboard error
Keyboard locked -
Unlock key switch
Check the keyboard connection. If the connection is secure the keyboard
or keyboard controller might have failed. If the problem persists replace
the defective component.
Monitor type does not match
CMOS - Run SETUP
Run the BIOS Setup utility and set the correct monitor type.
Operating system not found
The operating system cannot be found on drive A or drive C.
Run the SCU and correctly identify drive A or drive C.
Correctly install the operating system. Refer to the supplied operating
system documentation.
Parity check 1 nnnn
Parity error found in the server bus. The BIOS attempts to locate the
address and display it on the monitor screen.
Parity check 2 nnnn
Run the SCU and restore all settings to original values.
If the problem persists replace the defective component.
Press <F1> to resume, <F2> to
Setup
This message appears after any recoverable error message.
Press <F1> to reboot or <F2> to enter the BIOS Setup utility to make
any necessary changes.
Real time clock error
Real-time clock failed BIOS test.
Replace the battery and then run the SCU to restore previous
configuration information.
Shadow RAM Failed at offset:
nnnn
Shadow RAM failed.
Run the SCU and disable failed shadow memory region.