SBB LED Status Indicators

The hot-swap backplane monitors shelf status to identify error conditions or failures.  This status is displayed
on the SBB LEDs.  The left LED displays the device activity and the right LED displays the fault status.

♦ 

The left LED (green) is the device activity LED and is on or flashing when the SBB is active.

CAUTION

For non-RAID servers, removing a SBB when the  left LED is on or flashing can cause
the loss or corruption of data.

♦ 

For RAID servers, the right LED (amber) is the SBB fault LED and indicates an error condition when it
is either on or flashing.

Activity Status LED

Fault Status LED

Indication

On

Off

Device is operating properly.

Flashing

Off

Device is operating properly.

Off

Off

Device is inactive and operating
normally.  There is no fault.

On

On

Fault status, device is hung.
Replace SBB.

Off

On

Fault status, device is inactive
and spun down.  Replace SBB.

On

Flashing

Fault status, device is active and
spinning down due to a fault.

Содержание Prioris HX590 DP

Страница 1: ...S H X Service Maintenance Manual PRIORIS HX590 HX590 DP Server K MN SD00000 02 JG00 A Copyright Digital Equipment Corporation All rights reserved November 1995 NIJMEGEN THE NETHERLANDS MCS LOGISTICS...

Страница 2: ...Use duplication or disclosure by the U S Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS252 227 7013 Co...

Страница 3: ...XE 15 CONFIGURING THE SERVER 15 The SCU 16 Before Using the SCU 16 SCI Files and CFG Files 17 Using the SCU 17 Configure The Computer 18 Adding ISA Boards 19 SCU AND SETUP OPTIONS 19 SCU Main Menu 20...

Страница 4: ...he Optional Power Supply 46 Replacing Secondary Cache Memory 47 Replacing a Device Into the Hot Swap Drive Bay 48 SBB LED Status Indicators 49 Replacing the Server Battery Real Time Clock RTC 50 CONNE...

Страница 5: ...ss Map 69 PCI Configuration Space Address Map 69 Server Interrupt Levels 69 CHAPTER 6 PASS FAIL CRITERIA 71 APPENDIX A SERVICE NOTES 73 RECOMMENDED TOOLS 73 Other Needed Materials 73 Required Special...

Страница 6: ...38 Figure 3 8 Removing the CD ROM drive 39 Figure 3 9 Removing the CPU module 40 Figure 3 10 Replacing the CPU Chip 41 Figure 3 11 Set the CPU Voltage to 3 3 Volt 42 Figure 3 12 Removing the Memory M...

Страница 7: ...ument may not apply to the computer s you are servicing since many of the diagnostic tests are designed to test more than one product CAUTION Digital recommends that only A certified engineers attempt...

Страница 8: ......

Страница 9: ...riteback cache 64 bit memory card supporting up to 512 MB parity or 256 MB ECC memory On board Cirrus 5482 16 bit 512KB video memory 6 PCI slots 3 Primary and 3 secondary and 6 EISA I O slots 10 exter...

Страница 10: ...ernel Systems contain no SCSI controller and must be ordered with at least 16MB of DRAM memory With these systems either wide or narrow non RAID or RAID host controllers can be added Kernel systems ma...

Страница 11: ...ory Cache FDD HDD Host Contr CD ROM FR 881WW AA 32 MB parity 512KB 1 44MB None Adaptec 2940W 1 channel Wide SCSI 2 600 KB sec FR 881WW AB 32 MB ECC 512KB 1 44MB 4 x 1GB SCSI 2 1 channel Narrow RAID EI...

Страница 12: ......

Страница 13: ...mory ROM chip The BIOS initializes hardware and boots the operating system when the server is turned on The BIOS also provides access to other services such as keyboard and disk drive The server comes...

Страница 14: ...py the above files to it 4 Insert a blank formatted diskette into drive A 5 From drive C type MAKECRD This copies the files to drive A 6 Remove the crisis recovery diskette from drive A and store it i...

Страница 15: ...he diskette copy the new file to the upgrade directory and type PHLASH filename 5 Press Enter to continue If not press Esc to cancel Once Enter is pressed PHLASH EXE automatically updates the server s...

Страница 16: ...rams and their uses refer to the appropriate sections in this chapter to setup or update the server s configuration Otherwise carefully read and understand this chapterbefore attempting to modify the...

Страница 17: ...nstall any optional hardware for example disk drives EISA expansion boards and so on Refer to Chapter 3 Service Procedures 2 Make a backup copy of the supplied System Configuration Utility diskette St...

Страница 18: ...tep 1 Important EISA Configuration Information This menu item provides basic EISA configuration information and how it differs from ISA configuration These screens are available at any time during the...

Страница 19: ...elect Step 5 Save and Exit to save the configuration and exit the SCU Turn off the server and install the ISA boards CAUTION Do not attempt to physically install boards while the server is turned on S...

Страница 20: ...el of required server security you might need to access one or more of the menu items to properly configure the server When accessing the SCU a welcome screen appears followed by the main menu options...

Страница 21: ...server boots Extended memory Not user selectable Displays the amount of extended memory each time the server boots Boot Options Menu Fields Settings Comments Boot option A then C C then A C only Each...

Страница 22: ...o repeat a keystroke Memory and Cache Options Menu Fields Settings Comments Internal cache Enabled Disabled Enables or disables the server s internal cache External cache Enable Disable Enables or dis...

Страница 23: ...r disabled User password is Not user selectable Tells whether or not the user s password is enabled or disabled Set supervisor password Press Enter Enables to set a supervisor password Set user passwo...

Страница 24: ...s or disables onboard serial port 1 at the specified address Serial port 2 Auto Disabled 3F8 IRQ4 2F8 IRQ3 3E8 IRQ4 2E8 IRQ3 Enables or disables onboard serial port 2 at the specified address Diskette...

Страница 25: ...ween writes PCI burst write Enabled Disabled Enables or disables PCI memory burst write cycles PCI arbiter System default Pure rotating EISA slots PCI slots 4 6 CPU PCI slot 1 PCI slot 2 PCI slot 3 Se...

Страница 26: ......

Страница 27: ...s properly connected Keep circuit boards and components away from non conductors Keep clothing away from circuit boards and components Keep circuit boards in anti static bags Be cautious when AC power...

Страница 28: ...gent should be an all purpose cleaner that is used in house Required Special Tools None Remedial Diagnostic Test Software QAPLUS fe PC Advanced Diagnostic Software latest version Supplier information...

Страница 29: ...onnected to server 2 Turn server off 3 Unplug power cord from wall outlet 4 Disconnect power cord and monitor cord from server WARNING You might injure yourself or damage the server if you attempt to...

Страница 30: ...CPU module E Main logic board F Memory module G 3 inch diskette drive H Front access 5 inch half height drive bays I CD ROM drive bay J Integral hot swap device bay slots 0 through 6 from top to bott...

Страница 31: ...Right Side Legend Component A Power supply B Redundant power supply area C Storage backplane D Contact switch E Ac power plug F Monitor plug G SCSI knockouts back panel H Keyboard and mouse ports I S...

Страница 32: ...documentation for server memory address and IRQ requirements Compare that information to the server memory and IRQ requirements in the appropriate CPU module specifications booklet If conflicts are de...

Страница 33: ...any electronic component unless you are safely grounded Wear a grounded wrist wrap or touch an exposed metal part of the server s chassis Main Logic Board Jumper Settings Entries in Italic bold in th...

Страница 34: ...rocedures Digital PRIORIS HX590 HX590 DP Server 34 MCS Logistics Engineering Nijmegen P R I O R I S H X Main Logic Board Jumper Locations J28 J41 1 2 3 J38 J17 J9 J39 J42 Figure 3 5 Main Board Jumper...

Страница 35: ...d Parity memory and ECC memory cannot be mixed together Only 32 MB 2 x 16MB IBM ECC and 64 MB 2 x 32 MB IBM ECC densities are available for ECC memory modules Memory Configurations Bank 0 1 Bank 2 3 B...

Страница 36: ...128 MB 2 x 4 MB 2 x 32 MB 2 x 32 MB 136 MB 2 x 4 MB 2 x 64 MB 136 MB 2 x 8 MB 2 x 32 MB 2 x 32 MB 144 MB 2 x 8 MB 2 x 64 MB 144 MB 2 x 4 MB 2 x 4 MB 2 x 4 MB 2 x 64 MB 152 MB 2 x 16 MB 2 x 32 MB 2 x 3...

Страница 37: ...HX590 HX590 DP Server Service Procedures MCS Logistics Engineering Nijmegen 37 P R I O R I S H X PRIORIS HX590 HX 590 DP SIMM Locations Bank 7 Bank 6 Bank 5 Bank 4 Bank 3 Bank 2 Bank 1 Bank 0 Figure 3...

Страница 38: ...the 3 inch Diskette Drive To remove the 3 inch diskette drive 1 Turn off the computer 2 Disconnect external devices ac power and monitor power 3 Unlock and remove side panels 4 Disconnect power and ri...

Страница 39: ...M Drive To remove the CD ROM drive 1 Turn off the computer 2 Disconnect external devices ac power and monitor power 3 Unlock and remove side panels 4 Disconnect power and ribbon cables 5 Remove screws...

Страница 40: ...rnal devices ac power and monitor power 3 Unlock and remove left side panel 4 Remove CPU module retaining bracket 5 Carefully remove CPU module from main logic board 6 Replace CPU module and retaining...

Страница 41: ...module 2 Place the CPU module on an anti static surface 3 Lift up on the release lever for the ZIF socket 4 Remove the CPU from the ZIP socket pulling it straight up 5 Install the new CPU and return...

Страница 42: ...setting Set the CPU voltage to 3 3V 1 Remove the 5V Jumper Module form the 5V connector J100 on the CPU Module 2 Push the 3 3 V Jumper Module on the pins of 3 3V connector J101 on the CPU Module Make...

Страница 43: ...and monitor power 3 Unlock and remove left side panel 4 Remove memory module retaining bracket 5 Carefully remove memory module from main logic board 6 Install a higher performance memory module or a...

Страница 44: ...X Removing the Main Logic Board To remove the main logic board 1 Turn off the computer 2 Disconnect external devices ac power and monitor power 3 Unlock and remove side panels 4 Remove all connectors...

Страница 45: ...rn off the server 2 Disconnect external devices ac power and monitor power 3 Unlock and remove left side panel 4 Remove metal shield 5 Remove screws securing power supply to rear of chassis 6 Release...

Страница 46: ...rn off the server 2 Disconnect external devices ac power and monitor power 3 Unlock and remove left side panel 4 Remove metal shield 5 Remove screws securing power supply to rear of chassis 6 Release...

Страница 47: ...module 2 Place the CPU module on an anti static surface 3 Locate the secondary cache memory socket on the CPU module and remove the currently installed cache memory module CAUTION Static electricity...

Страница 48: ...to the next section SBB LED Status Indicators NOTE Not all SCSI host adapters support the hot swap method Refer to the SCSI host adapter documentation to determine if the hot swap method is supported...

Страница 49: ...s active CAUTION For non RAID servers removing a SBB when the left LED is on or flashing can cause the loss or corruption of data For RAID servers the right LED amber is the SBB fault LED and indicate...

Страница 50: ...uration settings using the SCU 2 Turn off the server 3 Disconnect external devices ac power and monitor power 4 Unlock and remove left side panel 5 Remove old battery 6 Install new battery Make sure p...

Страница 51: ...you connect to the server The server configuration SCSI adapter s and all SCSIdevices must work together for optimum performance When installing SCSI devices use the following guidelines to configure...

Страница 52: ...ble Note that The SCSI ID addressing is independent of the single or dual SCSI bus arrangement Make sure to select unique SCSI IDs for all SCSI devices on the SCSI bus You must use a wide SCSI host ad...

Страница 53: ...across the SCSI host adapters When arranging SCSI devices make sure each device connected to a SCSI host adapter is assigned a unique SCSI address Each operating system has different limitations rega...

Страница 54: ...apter ID7 channel A host termination B 68 pin to 50 pin adapter cable to CD ROM C 68 pin to 50 pin adapter cable to top right drive bay D Backplane 68 pin connector E Terminator F Jumper cable NOTE Th...

Страница 55: ...3 If necessary connect appropriate power cable to device 4 Replace and lock side panels 5 Connect external devices and restore power Dual Channel SCSI Bus Legend Legend Component A SCSI host adapter I...

Страница 56: ...nal SCSI bus 1 Remove the terminator from the storage backplane for the bus you want to connect 2 Connect the 68 pin unshielded cable connector to the storage backplane A 3 Using a screwdriver gently...

Страница 57: ...ives are spun down completely and then turn it back on If the POST detects an error refer to this chapter and take the appropriate steps to correct the problem After the problem has been resolved rest...

Страница 58: ...ent SIMM BIOS server battery etc BeepCode Error 2 2 3 BIOS ROM checksum 3 1 1 Test DRAM refresh 3 1 3 Test keyboard controller 3 4 1 Test 512K base address lines 3 4 3 Test 512K base memory 2 1 2 3 Ch...

Страница 59: ...ntify diskette drive A and or B Invalid NVRAM media type NVRAM access failed Run the SCU and restore all settings to original values If the problem persists replace the defective component Keyboard co...

Страница 60: ...CU and ensure that all settings are correct Save the configuration even when no changes are made If the problem persists replace the defective component System RAM failed at offset nnnn System RAM fai...

Страница 61: ...or cable is incorrectly installed Video controller has failed Incorrect VGA drivers installed Adjust the brightness and contrast controls Check all monitor connections Replace the failed component Ins...

Страница 62: ...ect the keyboard No response to mouse commands Mouse is password protected Mouse driver not installed Enter the keyboard and mouse password Install the appropriate mouse driver Server operates correct...

Страница 63: ...rive Operating system software is not installed on the SCSI boot hard disk drive Requested partition does not exist SCSI boot hard disk drive at wrong SCSI address Format the SCSI hard disk drive Prop...

Страница 64: ...eration Refer to Main Logic Board Jumpers Adjust the monitor brightness and contrast controls No monitor display while loading Windows video drivers Monitor type incorrectly set Set the correct monito...

Страница 65: ...QAPlus FE Error Messages Component Messages Solution CPU Arithmetic Function Failed General Functions Failed Exception Interrupt in Protected Mode Refresh Failure Logic Functions Failed Reset CPU Repl...

Страница 66: ...topped Invalid Date RTC Interrupt Failed Run Setup Replace battery clock CMOS CMOS Clock Test Failed Change time from Setup menu in QAPLUS Serial port COM port failed Serial Chip Error Serial Compare...

Страница 67: ...network expansion boards require a specific memory location If that location is already allocated a memory conflict results and the expansion board will not operate as expected Note that some memory I...

Страница 68: ...d by BIOS Setup during POST 48 KB EC000 to EFFFF SCSI BIOS if enabled 16 KB F0000 to FFFFF System BIOS memory 64 KB CPU I O Address Map Range hexadecimal Function 0000 to 0CF7 PCI I O space 0CF8 Confi...

Страница 69: ...o 3BE LPT3 if enabled 3F0 to 3F7 Diskette controller if enabled 3F8 to 3FF COM1 if enabled PCI Configuration Space Address Map Range hexadecimal Function C0xx CPU bridge C1xx PCI PCI bridge PCI slots...

Страница 70: ......

Страница 71: ...d Destructive Test Sequential write random read Destructive Test Floppy Disk All Tests Keyboard All Tests COM Ports All Tests LPT Ports All Tests Pointer device All Tests 3 Successful bootstrap of the...

Страница 72: ......

Страница 73: ...c wrist strap Other Needed Materials Cleaning agent should be an all purpose cleaner that is used in house Required Special Tools None Remedial Diagnostic Test Software QAPLUS fe PC Advanced Diagnosti...

Страница 74: ...R I S H X ECO FCO Information BIOS version information Refer to the Digital DECpc Bulletin Board Support for the latest information on BIOS upgrades Network locations North America South America Austr...

Страница 75: ...e Spares Catalogue EK A0836 RG Sevice Maintenance Manual Spares Catalogue EK A0815 SV On Line Bulletin Boards The most current product information and technical support is also available on line The m...

Страница 76: ......

Страница 77: ...e will do our best to make this document a valuable support to your service effort for Digital Please fill out the reader feedback form and send or fax it to Digital Equipment Parts Center b v Att MCS...

Страница 78: ......

Страница 79: ...Personal Notes...

Страница 80: ...Personal Notes...

Страница 81: ...Personal Notes...

Страница 82: ...Personal Notes...

Страница 83: ...on this form are used at Digital s direction Did you find errors in this manual If so specify by page What is your general reaction to this manual format completeness organisation etc Is the document...

Отзывы: