Example 1:
The expected response to a SHOW REPEATER command appears as follows:
DECbridge>SHOW REPEATER
Hub 1 slot 3 twisted pair, repeater, rev.1, 8 ports.
Hub 1 slot 4 ThinWire repeater, rev.1, 6 ports.
Hub 2 slot 3 ThinWire repeater, rev.1, 6 ports.
Hub 2 slot 6 twisted pair repeater, rev.1, 8 ports.
Hub 2 slot 8 twisted pair repeater, rev.1, 8 ports.
Note that both the DECrepeater 90T and DECrepeater 90C repeaters are
installed in the hub.
Example 2:
The response to a SHOW REPEATER command to a slot that contains a device
other than a repeater appears as follows:
DECbridge>SHOW REPEATER 1
No repeater responds.
Example 3:
The response to a SHOW REPEATER command to an empty slot appears as
follows:
DECbridge>SHOW REPEATER 7
No repeater responds.
Example 4:
The response to a SHOW REPEATER command for a particular repeater appears
as follows:
DECbridge>SHOW REPEATER 3
Hub 1 slot 3 twisted pair, rev.1, 8 ports.
Hub 1 slot 3 port 0 segment counter 0 status: operational
Hub 1 slot 3 port 1 segment counter 1 status: no carrier loopback
Hub 1 slot 3 port 2 segment counter 0 status: disabled
Hub 1 slot 3 port 3 segment counter 0 status: operational
Hub 1 slot 3 port 4 segment counter 1 status: no carrier loopback
Hub 1 slot 3 port 5 segment counter 1 status: no carrier loopback
Hub 1 slot 3 port 6 segment counter 1 status: no carrier loopback
Hub 1 slot 3 port 7 segment counter 1 status: no carrier loopback
Hub 1 slot 3 port 8 segment counter 1 status: no carrier loopback
Managing the DECrepeater 90FA 4–11