background image

 EVO Systems 31

Warranty

Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of 
one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any 
implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the 
products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance 
of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability 
under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include 
proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages 
whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other 
party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. 

Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use 
of this product signifies your acceptance of this warranty. 

BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are 
binding on the Seller. 

© 2002-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US 
patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259, 5886632. Canadian and international patents may 
also apply. 

Digiplex, InTouch, WinLoad and NEware are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the 
United States and/or other countries. 

Limitations of Alarm Systems

It must be understood that while your Paradox alarm system is highly advanced and secure, it does not offer any guaranteed protection against 
burglary, fire or other emergency (fire and emergency options are only available on certain Paradox models). This is due to a number of reasons, 
including by not limited to inadequate or improper installation/positioning, sensor limitations, battery performance, wireless signal interruption, 
inadequate maintenance or the potential for the system or telephone lines to be compromised or circumvented. As a result, Paradox does not 
represent that the alarm system will prevent personal injury or property damage, or in all cases provide adequate warning or protection.
Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other 
emergencies, such other tools include but are not limited to insurance coverage, fire prevention and extinguish devices, and sprinkler systems.
We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and 
developments.

Warning for Connections to Non-Traditional Telephony (eg. VoIP)

Paradox alarm equipment was designed to work effectively around traditional telephone systems. For those customers who are using a Paradox 
alarm panel connected to a non-traditional telephone system, such as "Voice Over Internet Protocol" (VoIP) that converts the voice signal from your 
telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as effectively as with traditional 
telephone systems. 
For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may 
be compromised. Or, if your VoIP connection becomes disabled, your telephone line monitoring feature may also be compromised. Other concerns 
would include, without limitation, Internet connection failures which may be more frequent than regular telephone line outages.
We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non-
traditional telephone system with your installation company.  They should be able to offer or recommend measures to reduce the risks involved and 
give you a better understanding. 

Содержание DGP2-641BL

Страница 1: ...VO Systems We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments EVO641 EVO641R DGP2 641BL DGP2 6...

Страница 2: ......

Страница 3: ...w Access Control Works 16 Trouble Display 17 Trouble Display 17 Event Record Display 18 Additional Features 19 Programmable Outputs PGMs 19 Keypad Settings 19 Modifying illumination settings on the DG...

Страница 4: ......

Страница 5: ...s and menus to guide you through the system s operations Your installer can even customize the messages on LCD keypads for your home or business The LED display of the DGP2 648BL LED will let you asse...

Страница 6: ...eypad will display the status of all its assigned areas ACTION Lights Access Stay Force Byp Mem Trbl and Prg Lights will illuminate according to the status of the system Numerical Lights Zones ON Zone...

Страница 7: ...the system reverts to a previous status or when an operation is incorrectly entered the keypad emits a continuous beep tone BEEEEEEEEEEP 2 2 Confidential Mode Your installer can program keypads to not...

Страница 8: ...ss ENTER when the area you want to view appears on the screen 3 Press CLEAR to exit In Area Status Display mode the following information will scroll on the LCD screen ready if all zones in the select...

Страница 9: ...u have access to more than one area select the area s you wish to Stay arm refer to section 3 1 on page 4 4 4 Instant Arming This feature is the same as Stay arming except that there is no Entry Delay...

Страница 10: ...all reinstates the zones that were bypassed the last time your system was armed To activate Bypass Recall 1 Enter your ACCESS CODE 2 Press the BYP button 3 Press the MEM button Zones bypassed the last...

Страница 11: ...he ACC button when the area you want to program appears on the screen 5 Enter the time you want the area to be armed according to the 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 6 Press the EN...

Страница 12: ...ACCESS CODE 2 In the case of a false alarm call your monitoring station quickly to advise them of the false alarm In the case of a burglar alarm leave the premises and call the Police from a safe loc...

Страница 13: ...other options are manually changed the System Master Code will immediately revert to its original programming You can assign a label name to a user access code at any point during the Programming Use...

Страница 14: ...e Pressing the FORCE key will delete the character or blank space found at the current cursor position ARM Delete Until the End Pressing the ARM key will delete all characters and spaces to the right...

Страница 15: ...o program user access codes If you wish to program user access codes using the NEware Software please contact your installer for information If the keypad emits a rejection beep at any point during th...

Страница 16: ...nd if PGMs are programmed by your installer the user can only control the PGMs Refer to section 9 1 on page 19 for a more detailed explanation of PGMs User Options see section 6 7 on page User Labels...

Страница 17: ...s Option 6 Stay Instant Arm When option 6 is ON the Stay and Instant arm features are enabled The user can now Stay or Instant arm their assigned areas Option 7 Force Arm When option 7 is ON the Force...

Страница 18: ...ature extends a user s scheduled access period through an Access Control door by the amount programmed by your installer For example if the user s assigned schedule for the door is Monday to Friday fr...

Страница 19: ...ming and Disarming with Card 7 2 1 Arming with Card presented to a door during its assigned Schedule refer to step 8 in section 6 5 1 on page 12 presented to a door within its assigned Access Level re...

Страница 20: ...e EVO641R DGP2 641RB keypad on Door 02 on Tuesday August 3 at 3 00 p m she will gain access to the room Figure 4 Example B If Bonnie presents her card to the reader or the EVO641R DGP2 641RB keypad on...

Страница 21: ...m serviced 8 1 1 Group 1 System 1 AC Failure The control panel has detected a power failure This means that your system is running on the backup battery If this trouble occurs when your establishment...

Страница 22: ...cess Granted You will only be able to view the events that occurred in the area s assigned to your user access code Only available on LCD keypads To view the Event Record 1 Enter your ACCESS CODE 2 Pr...

Страница 23: ...E Your keypad will emit a Confirmation Beep The ACCESS action light will flash 2 Press the 6 key Your keypad will emit a Confirmation Beep the Prg action light will illuminate and the numerical light...

Страница 24: ...s will stop beeping when opened HH MM 4 Press CLEAR to exit chime programming 9 6 Panic Alarms Your system can be programmed to send an alarm to your monitoring station to request help from the polic...

Страница 25: ...set by your installer 4 When the VDMP3 answers the line you are prompted to enter your access code 5 Options are given to arm disarm 1 and control features PGMs 2 Not connected to an answering machine...

Страница 26: ...22 User Guide...

Страница 27: ...use your system requires no maintenance other than regular testing We recommend that your installer change the battery every three years 11 4 System Test Speak to your installer before conducting a S...

Страница 28: ...ke detector 3 If the problem remains after 90 seconds the alarm will sound again Press CLEAR again 4 The system will delay reporting the alert for another 30 seconds If you are unable to cancel the fa...

Страница 29: ...ires 12 5 Home Fire Warning System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire install smok...

Страница 30: ...ramming the user labels of a Hebrew LCD keypad Instead of using Table 2 on page 10 and Table 3 on page 11 use Tables 9 and 10 below Refer to section 6 3 on page 9 for information on programming user l...

Страница 31: ...amming the user labels of a Russian LCD keypad Instead of using Table 2 on page 10 and Table 3 on page 11 use Tables 11 and 12 below Refer to section 6 3 on page 9 for information on programming user...

Страница 32: ...15 s 131 147 163 179 195 211 227 e 243 y 020 036 052 4 068 D 084 T 100 d 116 t 132 148 164 180 196 212 G 228 z 244 w 021 037 053 5 069 E 085 U 101 e 117 u 133 149 165 181 197 213 229 h 245 q 022 038 0...

Страница 33: ...Touch 6 Quick Function 20 Bypass Bypass Recall 6 Programming 5 C Card Access Control Arming with 15 Disarming with 15 Characters Special 11 Chime Zones 20 Clock Set Time and Date 19 Code Follows Sched...

Страница 34: ...cters 11 Special Characters Greek 28 Special Characters Hebrew 26 Special Characters Russian 27 Special Function Keys 10 Standard Fire Zone 24 Stay Arming 5 System Master Code 9 System Test 23 T Tampe...

Страница 35: ...ions of Alarm Systems It must be understood that while your Paradox alarm system is highly advanced and secure it does not offer any guaranteed protection against burglary fire or other emergency fire...

Страница 36: ...rt in Canada or the U S call 1 800 791 1919 Monday to Friday from 8 00 a m to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 0...

Отзывы: