32
7.2
Solving problems
Defect
Possible causes
Action
·
It will not turn
on.
·
The power supply’s input
cable is not connected
properly
·
The circuit breaker is off.
·
Check the cables
and the fuse.
·
It does not
activate the
electromagnet
(turnstile cannot
be locked).
·
The cable is broken or the
distance between the
electromagnet and the
locking device is
maladjusted.
·
Adjust the
electromagnet or
forward the
equipment to the
Technical
Assistance.
·
The arm does not
remain in the
correct position.
·
There is wear, dirt, a
broken spring or lack of
lubrication in the sphere
base.
·
Request a
replacement for
the faulty part or
forward the
equipment to the
Technical
Assistance.
·
It does not lock
in the first
tooth.
·
The distance between the
electromagnet and the
locking device is
maladjusted.
·
Adjust the
electromagnet or
forward the
equipment to the
Technical
Assistance.