ca
Vca
20
The following sections concern important aspects of CATRAX Automatic Clip control
board configuration and connections of CATRAX Automatic Clip.
6.5.1 Inputs
The input signals or passage clearance (HAB1 and HAB2) or anti-panic (BQC) can be
originated by a relay contact, pushbutton contact, tension from 5 to 24 Vca/cc, from
110 to 220 Vca/cc. To enable passage through relay contact or pushbutton, make the
connection as shown below:
INFORMATION:
- The engine (CN4) and electromagnets (CN18) cables
are provided alongside CATRAX Automatic Clip.
CN9
OUTPUTS
1
NO or NC Contact (HAB1 return)
2
Contact C (HAB1 return)
3
NO or NC Contact (HAB2 return)
4
Contact C (HAB2 return)
5
Output for indicative X (open collector NPN – maximum 500 mA)
orange wire
6
Output for arrow > (open collector NPN – maximum 500 mA) blue
wire
7
Output for arrow < (open collector NPN – maximum 500 mA)
green
wire
8
+24V c (indicative arrows' power) red wire
d
9
GND (indicative arrows' power) black wire
10
+ solenoid of badge collector box
11
- solenoid of badge collector box
12
Sound signal (open collector – NPN)
CN10
SOL BQC
1
(+) 24V c
d
2
SIGNAL
CN14
BQC SENSOR
1
(+) 2 4V c
d
2
SIGNAL
CN18
ELECTROMAGNETS
1
(+) electromagnet 1
2
(-) electromagnet 1
3
(+) electromagnet 2
4
(-) electromagnet 2