Configure the device using the ConnectPort LTS web interface
Configuration through the web interface
Digi ConnectPort LTS User Guide
71
n
Establish connection under one of the following conditions
:
l
Always connect and maintain connections
: A connection is always available. If a
connection is lost it will be reconnected automatically. This type of connection is most
often used in client/server configurations where this Digi device server is the client.
Note
Select this option to enable autoconnect for 3-wire devices.
l
Connect when data is present on the serial line
: A connection is made when the serial
port receives data. This type of connection is most often used for terminals and terminal
emulation.
l
Match string
: A 1 to 4 character string. This is usually the newline character sequence but
can also be a custom string of 1 to 4 characters.
l
Strip string before sending
: Search for the string specified in the Match String field
before sending the data and strip the string from the string from the data before it is sent
to the destination.
l
Connect when DCD (Data Carrier Detect) line goes high
: A connection is made when the
serial port's DCD (Data Carrier Detect) signal goes high. This type of connection is most
often used for modems. See the
for the option to close the
connection when the DCD signal goes low.
Note
If you are using 8-wire cabling, you must apply the altpin for DCD functionality.
l
Connect when DSR (Data Set Ready) line goes high
: A connection is made when the
serial port's DSR (Data Set Ready) signal goes high. See the
for
the option to close the connection when the DSR signal goes low.