Troubleshooting Guide

Problem

Things to try:

Low DNA 

recovery

Run some of the untreated and RapidTip2 purified 

PCR on a gel to check your amplicon band 

intensity.

Note: Purify at least 45 μl of your PCR reaction to 

optimize DNA recovery.

Slow or 

difficult 

aspiration

Check that pipettor volume is 

50 or 60 μl??

.

Check that tips are firmly attached to the pipettor.

Note: Diffinity RapidTip2 is incompatible with 

detergents, mineral oil, and ready-to-load PCR mixes 

that contain density increasing compounds.

Fluid 

remains 

in the 

RapidTip2

It’s normal for a small amount of liquid (~10 μl) to 

remain inside the Diffinity RapidTip2.

Note: Overdispense or blowout all fluid on the last 

dispense cycle. 

Failure to 

remove 

impurities

Verify that particles are at the bottom of the 

tip prior to sample treatment; the pipettor is 

operating at the proper (slow) speed settings; 

and that particles are effectively mixing with the 

sample during pipetting.

Note: Remove trapped air bubbles by gently “flicking” 

the pipettor downward for additional aspirate/dispense 

cycles.

Visit www.diffinitygenomics.com/FAQs.asp for additional 
information.

Содержание RapidTip2

Страница 1: ...otice For optimal purification results sharply tap the RapidTip2 package 2 3 times on a flat surface so that the particles drop to the bottom of the tips Version B March 2012 For PCR Purification with...

Страница 2: ...y Control 5 Technical Assistance 5 Safety Information Disposal 5 Product Specifications 6 Introduction 7 Diffinity Technology Principle 8 Equipment to be Supplied by User 9 Guidelines Pipetting with t...

Страница 3: ...ity RapidTip2 for PCR Purification with Polymerase Removal 1 Box of 48 RapidTip2s RR050 096 RR050 096L Diffinity RapidTip2 for PCR Purification with Polymerase Removal 1 Box of 96 RapidTip2s L denotes...

Страница 4: ...asing compound Product Warranty and Satisfaction Guarantee Diffinity Genomics will guarantee the performance of Diffinity RapidTip2s for the uses and performance as described in our product literature...

Страница 5: ...nce Call 1 877 362 1812 between 8am and 4pm Eastern Time Monday through Friday or visit www diffinitygenomics com for help with common questions Safety Information Disposal Diffinity RapidTip2s may be...

Страница 6: ...0bp to 10Kb Impurity Removal dNTP primers primer dimers up to 90 less than 40 50 bp DNA Polymerase removal Taq Hot Start High Fidelity up to 1 1000 dilution with no measurable amplification activity D...

Страница 7: ...emoves dNTPs primers primer dimers and DNA polymerase while providing up to 90 recovery of pure DNA fragments ranging in length from 100bp to 10Kb It dramatically reduces the amount of time to purify...

Страница 8: ...urifies PCR solutions and removes DNA polymerase comparably to popular spin column methods The positive control con tains polymerase and all PCR reagents but did not undergo purification and therefore...

Страница 9: ...how improved peak quality and lower background in Diffinity RapidTip2 purified samples as compared to unpurified samples Equipment to be Supplied by User PCR Sample 50 l 5 l Tubes to store purified DN...

Страница 10: ...ate the rest of the sample and dispense 2 Mix effectively For effective mixing it is important that the particles remain in contact with the sample during each aspirate and dispense cycle Aspirate slo...

Страница 11: ...mple gently flick the pipettor downward to bring them back into contact with the sample and proceed with mixing Pipetting Examples Please note that typical PCR samples are colorless for visualization...

Страница 12: ...particles that purify a PCR reaction these particles can adhere to the pipette tip walls during shipping For optimal results sharply tap the box 2 3 times on a flat surface so that particles are at th...

Страница 13: ...sary to drive liquid completely out of the tip on every dispense The particles should mix completely with the solution and make it appear cloudy while inside the tip 6 Dispense all solution into a cle...

Страница 14: ...to load PCR mixes that contain density increasing compounds Fluid remains in the RapidTip2 It s normal for a small amount of liquid 10 l to remain inside the Diffinity RapidTip2 Note Overdispense or...

Страница 15: ...dwide For a complete list visit our website 2 Call Diffinity Genomics Customer Service and place the order by phone 1 877 362 1812 3 Visit our website and place an order online via the online Diffinit...

Страница 16: ...es Diffinity Genomics Inc 150 Lucius Gordon Drive West Henrietta NY 14586 2011 Diffinity Genomics Inc All rights reserved Diffinity Genomics Diffinity and RapidTip are trademarks of Diffinity Genomics...

Отзывы: