• 8 •
TroUBLESHooTIng
10.
ProBLEM
rEASon
SoLUTIon
Red LED is on, audible
alarm is on, and/or inverter
does not function.
Poor contact at terminals.
Fuse Blown.
Inverter shutdown.
Inverter may not be working
properly.
Unplug and reinsert the
12-volt plug or check
connections at power supply.
See “IF THE INVERTER
FUSE BLOWS” section.
See “LED INDICATOR AND
SHUTDOWN PROTECTION”
section.
See Warranty and call
Customer Service 1-800-
732-7764 (Hours: 7 am – 5
pm CST).
The red LED is lit and the
green LED is not.
12V Accessory Plug or
Clips are not making a good
connection to the battery.
Connections are reversed.
Inverter may not be working
properly.
Check for poor connection to
battery and frame. Make sure
connection points are clean.
Rock clips back and forth for
a better connection.
Unplug the charger and
reverse the clips.
See Warranty and call
Customer Service 1-800-
732-7764 (Hours: 7 am – 5
pm CST)
SPECIfICATIonS
11.
Maximum Continuous Power
425 Watts
Surge Capability (Peak Power)
850 Watts
No Load Current Draw
<0.4A
Wave Form
Modified Sine Wave
Input Voltage Range
10.5V – 15.5V DC
Output Voltage Range
110V ± 5% AC
Low Battery Alarm
Audible, 11V ± 0.3V DC
Low Battery Shutdown
10.5V ± .3V DC
High Battery Shutdown
15.5V ± 0.5V DC
Optimum Efficiency
85%
AC Outlet
Two, NEMA 5 - 15 USA
Fuse
Two, 25-Amp (Spade Type)
Dimensions
6.5” L x 4.13” W x 2.2” H
Weight
approximately 2 lbs.