DieHard 71496 Скачать руководство пользователя страница 10

• 6 •

noTE

: If more than one device is to be powered, start one device at a time to avoid a power 

surge and overloading the inverter. The surge load of each device should not exceed the inverters 

Continuous Operation wattage rate.

 If you are using the power inverter to operate a battery charger, monitor the 

temperature of the battery charger for about 10 minutes. If the battery charger becomes 

abnormally warm, disconnect it from the inverter immediately.

noTE: 

You can use an extension cord from the inverter to the device without significantly 

decreasing the power being generated by the inverter. Use a 18 gauge (AWG) (1.75mm

2

extension cord. For best operating results, the extension cord should be no longer than 50 feet  

(15 meters).

Using the Inverter to operate a TV or Audio device:

The inverter is shielded and filtered to minimize signal interference. Despite this, some interference 

may occur with your television picture, especially with weak signals. Below are some suggestions 

to try and improve reception.

Make sure the television antenna produces a clear signal under normal operating 

1. 

conditions (i.e. at home plugged into a standard 120-volt AC wall outlet). Also, ensure that 

the antenna cable is adequately shielded and of good quality.
Try altering the position of the inverter, antenna cables, and television power cord. Add 

2. 

an extension cord from the inverter to the TV so as to isolate its power cord and antenna 

cables from the 12-volt power source.
Try coiling the television power cord and the input cables running from the 12-volt power 

3. 

source to the inverter.

Affix one or several “Ferrite Data Line Filters” to the television power cord. Ferrite Data 

4. 

Line Filters can be purchased at most electronic supply stores.
Try grounding the inverter with an 18 AWG (minimum) (0.75mm

5. 

2

) wire, using as short a 

length as possible.

noTE

: You may hear a “buzzing” sound being emitted from inexpensive sound systems when 

operated with the inverter. This is due to ineffective filters in the sound system’s power supply. 

Unfortunately, this problem can only be resolved by purchasing a sound system with a higher 

quality power supply or higher quality filter.

PoWEr SoUrCE

7. 

When operating a device that draws approximately 60 watts, your average automobile or marine 

battery at full charge will provide an ample power supply to the inverter for approximately 3 hours 

when the engine is off. The actual length of time the inverter will function depends on the age and 

condition of the battery and the power demand being placed by the device being operated with  

the inverter.
If you decide to use the inverter while the engine is off, we recommend you turn OFF the device 

plugged into the inverter and disconnect the inverter’s plug from the 12-volt accessory outlet before 

starting the engine. To maintain battery power, start the engine every 2 to 3 hours and let it run for 

approximately 30 minutes to recharge the battery.

Although it is not necessary to disconnect the inverter when turning over the engine, it may briefly 

cease to operate as the battery voltage decreases. While the inverter draws very low amperage 

when not in use, it should be unplugged to avoid battery drain.

Содержание 71496

Страница 1: ...s product Lea todas las Instrucciones de Operaci n y Reglas de Seguridad as mismo apl quelas a cada uso del producto ATENCI N Sears Brands Management Corporation Hoffman Estates IL 60179 U S A OWNER S...

Страница 2: ......

Страница 3: ...Full Warranty When operated and maintained according to all supplied instructions if this DieHard product fails due to a defect in material or workmanship within 1 year from the date of purchase retu...

Страница 4: ...EPUESTO 18 UN A O DE GARANT A TOTAL EN DIEHARD Cuando se opere o maneje con las debidas precauciones de acuerdo a las instrucciones si el DieHard falla en alguno de sus componentes de fabricaci n dura...

Страница 5: ...e or property damage Safety messages in this manual contain two different type styles Unnumbered type states the hazard Numbered type states how to avoid the hazard The icon gives a graphical descript...

Страница 6: ...ome with your inverter 1 12 Incorrect operation of your inverter may result in damage and personal injury 1 13 The inverter output is 110V AC and can shock or electrocute the same as any ordinary hous...

Страница 7: ...hile testing devices and equipment within the wattage range of the inverter If a device does not operate properly when first connected to the inverter turn the inverter rocker switch ON I OFF O and ON...

Страница 8: ...battery clips 425 watt output maximum or the 12V accessory plug 100 watts maximum Locate the positive and negative plastic terminals located on the right side of the inverter 1 and remove the terminal...

Страница 9: ...or fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block To disconnect the inverter reverse the above steps 5 NOTE The internal speaker may make a brief...

Страница 10: ...wer cord and the input cables running from the 12 volt power 3 source to the inverter Affix one or several Ferrite Data Line Filters to the television power cord Ferrite Data 4 Line Filters can be pur...

Страница 11: ...air flow over and through the inverter Reduce the load on the inverter to the continuous rated output RESET To reset after shutdown occurs switch the inverter On Off switch to the OFF position Check t...

Страница 12: ...nections are reversed Inverter may not be working properly Check for poor connection to battery and frame Make sure connection points are clean Rock clips back and forth for a better connection Unplug...

Страница 13: ...9 REPLACEMENT PARTS 12 12V Accessory Plug with Cables 38 99 002175 Battery Cable with Clips 38 99 001512...

Страница 14: ...se describen dos tipos de estilo Los que aparecen sin n mero indican el riesgo Aquellos que aparecen numerados indican c mo evitar los riesgos La figura muestra una descripci n gr fica del potencial...

Страница 15: ...clavija de CA est n ajustadas No modifique el inversor de ninguna forma incluyendo los cables enchufes interruptores o receptors de CA esto podr a causar serios da os personales o materiales No trate...

Страница 16: ...una prueba para establecer si el convertidor operar una pieza particular de equipo o dispositivo En caso de una sobrecarga de corriente el convertidor est dise ado para apagarse autom ticamente sa ca...

Страница 17: ...CABLES DEL CONVERTIDOR 5 El convertidor y la fuente de energ a deben estar en el modo APAGADO OFF IMPORTANTE Aseg rese de conectar su convertidor a una fuente de energ a de 12V solamente CONEXI N DEL...

Страница 18: ...RO al chasis del veh culo o al bloque motor alejado de la bater a No conecte el gancho al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco...

Страница 19: ...de poder generado por el inversor Se recomienda una extensi n de calibre 18 AWG de 0 75mm2 Para obtener mejores resultados la extensi n no debe sobrepasar 50 pies 15 metros Para Usar El Convertidor P...

Страница 20: ...ltaje de la bater a Aunque el convertidor extrae muy poco amperaje cuando no est en uso debe ser desconectado para evitar descargar la bater a INDICADOR LED Y PROTECCI N DE DE APAGADO 8 El LED brilla...

Страница 21: ...4 IMPORTANTE No intente instalar un fusible de m s de 25 amps ya que esto podr a da ar el inversor y cualquier producto que use con el inversor Aseg rese de corregir la causa del fusible quemado ante...

Страница 22: ...a y llame al Servicio al Cliente al 1 800 732 7764 Horario De 7 a m a 5 p m CST Tiempo del Centro ESPECIFICACIONES 11 M xima Energ a Continua 425 Watts Capacidad de Tensi n Potencia M xima 850 Watts C...

Отзывы: