56
Technical manual: SQUARE 940-2
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
E05
Reference switch - Short circuit or wire
break
Check the reference switch.
E06
The reference switch operates in the
wrong position.
When using a rotary encoder, the reference
switch has been activated in the wrong
position or when using a limit switch, the „Pre
close“ limit contact is open.
E07
Running time exceeded.
Check the setting of parameter *6.
E08
The safety edge test failed.
Check the safety edge connections.
E09
Connection error on the safety edge
1.
Check the safety edge 1 connections.
E10
Safety edge 1 has been activated.
Check the door for mechanical obstacles
when opening.
E11
Connection error on the safety edge
2.
Check the safety edge 2 connections.
E12
Safety edge 2 has been activated.
Check the door for mechanical obstacles
when closing/opening.
E14
Communication error with the absolute
limit switch.
Check the wiring to the absolute limit switch.
E15
Reset limit positions failed.
Try to repeat the Quick Setup installation or run
Position Setup again.
E17
Fire signal activated.
Check the input signal on “fire“ signal.
E18
Xnet-Wireless Airlock could not allow
opening.
E19
Xnet-wireless no response
E21
SCip-Wireless - Remote timeout
E22
SCip Wireless - Safety edge timeout
E23
SCip Wireless - Safety edge
connection error