34
◄
”fully open” position
◄
Pre open
◄
Part open
◄
Photocell OFF
◄
Safety edge OFF
◄
Pre closed
◄
“fully closed“ position
»
Technical manual: SQUARE 940-2
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
The door controller uses position counts generated by the externally connected rotary encoder.
The door position is thus recognized and the door can be navigated through the various posi-
tions.
Depending on the encoder type, it may be necessary to install a reference switch/point so that
the controller knows where the door is when it is switched on.
The example shows a roller shutter with the different door positions within the door travel.
5.11 LIMIT SETUP
Submenu
Description
Operation Mode Select the operating mode. - See the descriptions under Operation Mode.
Quick Setup
Calls the quick configuration. Set limit positions. See section Commissioning.
Closed Limit
Set the position manually for the following door positions. Move the door with
the UP or DOWN button and save. The position can be saved by pressing the
MENU/ENTER button. The display shows “stored“ and returns to the existing
menu.
Pre Closed Limit
Pre Open Limit
Open Limit
Part Open
S. Device OFF
P. Cell 1 OFF
P. Cell 2 OFF
High Torque
This function is intended for sliding doors where a high torque is required in
the first and last part of opening and closing. This activates the value for “High
boost“ from the fully closed position and the set “Position distance“ in this pa-
rameter and also in the fully open position minus the distance in this parameter.
Set to 0 to deactivate.
5.10 DOOR POSITION