54
Technical manual: SQUARE 940-2
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
5
Ready:
Quick Setup is ready. The calculated values are now saved.
The operating mode is set to Auto.
If an error occurs, the error code E17 is displayed. The limits are
then reset. In this case, you must start again from step 1.
6
Completion
Commissioning:
The display from step 5 changes to “Find Ref“ after approx. 3
seconds. To initialize the normal operating mode, the reference
point must now be approached again. This is now done via the
connected command generators in deadman --> If the mechanical
stop OPEN was selected as reference, an OPEN command must
be issued. If the mechanical stop CLOSED has been selected, a
CLOSE command must be issued.
IMPORTANT
After the end positions have been learned during initial startup, the
motor load and the power reserve of the operator must be checked.
To do this, change the value in Express menu item 5.6 to „Motor Cur-
rent“. The motor current is now displayed in amperes on the home
screen.
The maximum ampere value for continuous operation can be read on
the motor nameplate at 230V.
Depending on local requirements and the ED of the system, the motor
current shown in the controller display should not exceed the rated
value of the motor.
Short-term exceeding of the nominal value during acceleration travel of
the door and / or during positioning travel of the door in the area of the
end positions by up to 50% is possible. It is essential to also check the
current consumption of the motor during the reference run!
The following applies: The higher the ED / actuation frequency, the
lower the value of an exceedance of the rated current indicated on the
motor should be.
In case of discrepancies of the indicated current value (e.g. with 0.18
KW MultiMove nominal value 1.3 A, actual motor current permanently
1.7 A) consult Dictator Technik.