5.12.3 Inputs
Options
Submenu
Description
X2.1 bis X2.5
Input
Select the input to be configured.
Function
Select the function for the input.
X4.1 bis X4.10
Name
Select the text linked to the input.
Logic
Select the logic function for the NO/NC input.
Eingangsfunktion Description
No Function
If the input is not used, set this value.
Flip Flop
Press the button to open or close the door. Closing only possible from
complete opening. Auto close timer active.
Open Fully
Move the door to the completely open position.
Open Fully with
auto close
Move door to the completely open position and start Auto Close Timer 1.
Stop
The door stops with stop ramps.
Close
The door closes.
Emergency Stop
The door stops with emergency ramps - To comply with Cat 2/P.L. D. this
input must be connected to X5.6 - X5.10.
Safety Edge
Possibility of connecting a contact edge.
Attention: Input not monitored!
Open/Stop/
Close
Press button to open, stop or close the gate.
Attention: This input must be connected to X5.1 - X5.4.
Photocell
Stops and opens the door - Deactivated by Par. 10.
Lock Open
Locks the door in the open position.
Lock Close
Locks the door in the closed position.
Open Dead man
The door opens while the input is active, otherwise the door stops.
Close Dead man
The door closes while the input is active, otherwise the door stops.
Breakout
Stops the door and activates „Dead-man“ operation.
Open Part 1
Door opens to “Part open 1“ position.
Part 1 AUT
Automatic closing “Part open 1“ position.
F.F. REV
Same as Flip Flop, but with the option of approaching the reference point.
F.F. Part 1
Opens to “Part 1“ position and closes.