background image

5.3.b DRAIN (Fig. 7) 

Fix the water drain pipe (10)

 

in the housing provided on the rear of the appliance 

(front for the 

flush-mounting models)

. Make sure that: 

• the pipe is a hose
• the internal diameter is 22 mm, as required
• the water drain hose is not throttled at any point throughout its length
• the drain hose slopes downwards by at least 15%

It is advisable to drain the water straight into an open drain trap. 

5.4 CONNECTION TO THE ELECTRICITY MAINS 

 

 IMPORTANT

:

 

the appliance must be connected to the electricity mains by professionally qualified personnel in

accordance with the Manufacturer’s instructions

 

before connecting the appliance to the electricity mains, make sure that the mains voltage rating
corresponds to the value indicated on the rating plate 

make sure that the appliance is connected to an efficient earthing system

make sure that the capacity of the power supply system suits the maximum power value indicated
on the rating plate of the appliance

if the appliance comes supplied with a plug, prepare a socket controlled by an omnipolar circuit-
breaker (7 in Fig. 4), with a contact-opening gap of not less than 3 mm, in accordance with national
safety standards currently in force. This switch must be equipped with fuses, with the associated
residual current device positioned in such a way as to be readily accessible. Insert the plug into the
socket controlled by the switch (7 in Fig. 4)

the plug must only be replaced by professionally qualified and authorized personnel, and the new
plug must comply with current national safety standards

if the appliance comes supplied without a plug and you wish to connect it permanently to the power
supply, prepare an omnipolar circuit-breaker (7 in Fig. 4), with a contact-opening gap of not less
than 3 mm, in accordance with national safety standards currently in force. This switch must be
equipped with fuses, with the associated residual current device positioned in such a way as to be
readily accessible. 

This operation must be carried out by a specialized technician

make sure that you fully uncoil the power supply cable and check that it is not crushed in any way

should the supply cable be damaged, it must be replaced by a specialized technician using a
special cable available from the Manufacturer or from the Technical Service Centres

6  START-UP 

6.1 CLEANING INTERNAL PARTS 

The appliance will have already been cleaned in the factory. However, you are advised to wash the 
internal parts again before using the appliance. Make sure that the power supply cable is unplugged 
before carrying out the above cleaning operation. 

See cleaning and sanitizing manual for information regarding cleaning operations.

 

For cleaning operations in general, use an ordinary detergent for washing dishes or a solution of water 
and vinegar. Rinse thoroughly with plenty of cold water and remove any ice that may have been 
produced during the first 5 cycles after cleaning, together with any ice present in the bin.  

It is advisable to avoid using abrasive detergents or powders, since these might damage the finish.  

6.2 START-UP  
When you start up the appliance the first time, or when you start it up again after a long period at 
a standstill, fill the basin manually with water (Fig. 8).

 

This filling operation must be carried out by opening the door, raising the flaps (if any) and pouring the 
water directly into the internal basin. 
In the cycles subsequent to the initial one, the appliance will be filled with water in a fully automatic way. 

Содержание ICE32A

Страница 1: ...Mod ICE32A Production code CB316A 11 2007 ...

Страница 2: ...It is strictly forbidden to reproduce this instruction manual or any part thereof AUTOMATIC ICE CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed 11 2007 ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...UP 6 2 a STARTING UP MODELS WITH CONTINUOUS DELIVERY 7 MAIN CAUSES OF OPERATING FAILURE 8 OPERATION 8 1 MODEL WITH CONTINUOUS DELIVERY 8 1 a ADJUSTING DISPENSED QUANTITY 8 2 MODEL WITH COLD WATER DISPENSER 9 MAINTENANCE 9 1 CLEANING THE FILTER OF WATER SUPPLY SOLENOID VALVE 9 2 AIR COOLED MODELS 9 3 CLEANING AND SANITIZING OPERATIONS 10 PERIODS AT A STANDSTILL The figures in this manual are of a g...

Страница 8: ...t make any attempt to repair the appliance yourself Contact only professionally qualified and authorized personnel in addition to rendering any form of warranty null and void modifying or attempting to modify this appliance is extremely dangerous open and close the door carefully without slamming it do not use the ice cube container to cool or preserve food or drinks as these operations could caus...

Страница 9: ...or from flowing back into the coolant circuit always make sure that the appliance is kept upright during transport storage and handling Follow the instructions given on the packaging 4 UNPACKING The appliance must be installed by authorized personnel in compliance with the current laws in force and the Manufacturer s instructions Once you have removed the packaging according to the instructions on...

Страница 10: ...hat hold the front panel in place and after opening the door pull out the panel from above Fig 6 Before fitting the appliance in place the power cable must be fixed to the base plate as shown in the diagram in Fig 6 pass the plug and cable 11 through the hole 12 in the plate position the cable clamp 13 in its housing Fit the front panel back in place after making these connections 5 3 CONNECTION T...

Страница 11: ...y to the power supply prepare an omnipolar circuit breaker 7 in Fig 4 with a contact opening gap of not less than 3 mm in accordance with national safety standards currently in force This switch must be equipped with fuses with the associated residual current device positioned in such a way as to be readily accessible This operation must be carried out by a specialized technician make sure that yo...

Страница 12: ...that the appliance is not touching furniture or sheet metal which can give rise to noise or vibrations should any trace of water appear check the drain hole of the container to ensure that it is not clogged that the water fill and drain pipes are correctly connected and are not throttled or damaged make sure that the temperature of the air or water does not exceed the installation limit values see...

Страница 13: ...e water inlet solenoid valve proceeding as follows switch off the electric power supply by means of the switch 7 in Fig 4 fitted during installation and disconnect the plug of the appliance from its socket if any shut off the water supply by turning the tap 8 in Fig 4 fitted during installation unscrew the threaded ring nut 14 of the water feed hose located at the outlet of the solenoid valve at t...

Страница 14: ... the chemical and physical features of the water and after every period in which the appliance has remained at a standstill for any length of time You are advised to ask your dealer to draw up a scheduled maintenance contract that will cover the following cleaning the condenser cleaning the filter located on the water supply solenoid valve cleaning the ice tray checking the charge of coolant gas c...

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...he hot gas valve Clean the hot gas valve or replace it Water blow by through the evaporator water inlet valve Replace the valve The compressor doesn t compress Replace the compressor For air cooled models The fan is out of order Check the fan motor If necessary replace it Check the correct working of the pressure switch Anomaly THE ICE MAKER REMAINS WITHOUT WATER IN THE BASIN Cause Remedy No water...

Страница 30: ...p pipes Clean the pipes from the limestone Spray nozzles clogged Clean the spray nozzles Anomaly THE ICE MAKER DOESN T STOP WHEN THE BIN IS FULL Cause Remedy Bin thermostat Replace the thermostat or adjust it or check the probe position Anomaly THE ICE MAKER STOPS BY INTERVENTION OF THE WATER CONDENSER SAFETY THERMOSTAT PRESSURE SWITCH Water Leakage in the Condenser Cause Remedy No water supply to...

Страница 31: ...it make vacuum and charge Evaporator encrusted by limestone Remove the limestone from the whole evaporator but without roughening its surfaces The water inlet valve of the water condenser doesn t close Replace the anti interference condenser placed parallel to the pressure switch Replace the valve Anomaly SHEET OF ICE UNDER THE EVAPORATOR Cause Remedy Faulty or not adjusted evaporator thermostat R...

Страница 32: ...lean or direct the water jet toward the middle of the ice cubes Anomaly COMPRESSOR PROTECTION INTERVENTION Intermittent Working Cause Remedy Faulty power supply Check continuity the current carrying in Amp voltage of the electrical circuit Difficult condensation Check cleaning of the condenser and of the filter the fan working aeration in and out of the ice maker Starting capacitor out of order Re...

Страница 33: ...Anomaly THE PUMP LEAKS WATER Cause Remedy Slack pipe clips Check and clamp the clips Worn ceramic seal Replace the pump External gasket broken Replace the pump Anomaly THE PUMP DOESN T RUN Cause Remedy Lack of power supply Check the contacts of the timer micro switch Lack of power Replace the run capacitor Mechanical locking Replace the pump Interrupted winding Replace the pump ...

Страница 34: ... component Other electrical components short circuit and or low dielectric strength Replace the component Anomaly ICE PRODUCTION DECREASE Cause Remedy Condenser or air filter clogged Clean the filter and the condenser Bin flooded Check the water outlet pipes Ice maker without refrigerant Find the leak repair it make vacuum and charge Refrigerant blow by through the hot gas valve Clean the valve or...

Страница 35: ...on and compresses them increasing their temperature and pressure A condenser made up of a series of tubes refrigerated by cold water or ventilated air carries away the heat comprised in the gas from the compressor and helps in this way the gas liquefaction The refrigerating fluid now in liquid state circulates then in an evaporator that permits an optimal heat exchange with the out room by taking ...

Страница 36: ... the cubes basin and cools each small copper cup Water is sprayed on the evaporator cubes basin through the spray bar nozzles An ice layer due to the refrigerating fluid begins to form in the cups till these are completely full after some minutes Ice Falling Phase Defrosting Once the ice production time is finished the spray bar stops spraying water on the cubes basin and the hot gas valve assembl...

Страница 37: ...out room and is refrigerated by air coming from a fan run by an electric motor Both of them carry away the heat comprised in the gas that comes out from the compressor helping in this way the gas liquefaction Refrigerating Filter Capillar Tube The refrigerant filter stops possible impurities and the circuit humidity The gas in liquid status goes to the evaporator through this filter and the capill...

Страница 38: ...the compressor is piped to the condenser in order to get cool Hot gas valve Closed Suction line Capillar Tube Condenser Water Condenser Air Refrigerating filter Compressor Evaporator Cubes basin Defrosting The hot gas valve is open the compressed gas from the compressor is piped to the evaporator bypassing the condenser Hot gas valve Open Suction line Capillar Tube Condenser Water Condenser Air Re...

Страница 39: ...er falls into the basin restores the ideal level to start a new production cycle The second water inlet valve allows the water flow of the through the water condenser Water basin It gets water from the water mains It feeds the pump by a specific pipe provided with a filter Pump It draws out water from the water basin and pipes it under pressure to the spray bar Spray bar It gets water from the pum...

Страница 40: ... connected upstream the bin thermostat during the ice production phase so that the ice maker will stop only when the ice production phase is over The following scheme shows this working system Timer Utilizer Unit Bin thermostat Only in the ice production phase NB some components of the electrical circuit called Utilizer Units are always energized and do not depend on the timer status See the follo...

Страница 41: ...drop in temperature of the evaporator starts the timer in order to complete the ice production phase Defrosting The timer once reached the set up time simultaneously commutes three contacts letting the defrosting phase begin Evaporator thermostat Timer Hot gas valve Water inlet valve Evaporator The pump is stopped and also the spray noozles stop on the contrary the hot gas valve is started in orde...

Страница 42: ...hase allowing the water to flow on the evaporator and then into the water basin to restore the ideal water level to start a new cycle of ice cubes production Water inlet valve condenser This second water inlet valve allows the water to flow through the water condenser Contactor Energized the compressor Safety systems Safety thermostat Placed on the condenser of the water models It stops the machin...

Страница 43: ...iio o on n n Hydraulic Circuit Refrigerating Circuit Electric Circuit LINE CAMME 4 CAMME 3 CAMME 2 CAMME 1 EVAPORATOR THERMOSTAT BIN THERMOSTAT TIMER MOTOR CONDENSER CAPILLAR TUBE COMPRESSOR HOT GAS VALVE SUCTION LINE NEUTRAL WATER INLET VALVE WATER SUPPLY PUMP EVAPORATOR SPRAY BAR OVERFLOW TUBE GREEN LIGHT SWITCH on off GREEN LIGHT SWITCH on off ...

Страница 44: ...rating Circuit Electric Circuit LINE SAFETY THERMOSTAT EVAPORATOR THERMOSTAT BIN THERMOSTAT CAMME 4 CAMME 3 CAMME 2 CONDENSER PRESSURE SWITCH CONDENSER WATER DRAIN WATER INLET VALVE WATER SUPPLY SUCTION LINE NEUTRAL COMPRESSOR CAMME 1 TIMER MOTOR CAPILLAR TUBE WATER SUPPLY WATER INLET VALVE PUMP HOT GAS VALVE EVAPORATOR SPRAY BAR OVERFLOW TUBE GREEN LIGHT SWITCH ON OFF GREEN LIGHT SWITCH ON OFF ...

Страница 45: ... Hydraulic Circuit Refrigerating Circuit Elctric Circuit LINE CAMME 4 CAMME 3 CAMME 2 CAPILLAR TUBE CONDENSER CONDENSER PRESSURE SWITCH COMPRESSOR HOT GAS VALVE SUCTION LINE NEUTRAL FAN CAMME 1 TIMER MOTOR EVAPORATOR THERMOSTAT BIN THERMOSTAT WATER INLET VALVE WATER SUPPLY PUMP EVAPORATOR SPRAY BAR OVERFLOW TUBE GREEN LIGHT SWITCH ON OFF GREEN LIGHT SWITCH ON OFF ...

Страница 46: ...igerating Circuit Electric Circuit LINE SAFETY THERMOSTAT CONDENSER PRESSURE SWITCH CONDENSER CAMME 4 CAMME 3 CAMME 2 CAMME 1 TIMER MOTOR WATER DRAIN WATER INLET VALVE WATER SUPPLY NEUTRAL SUCTION LINE COMPRESSOR EVAPORATOR THERMOSTAT BIN THERMOSTAT CAPILLAR TUBE WATER SUPPLY WATER INLET VALVE PUMP HOT GAS VALVE EVAPORATOR SPRAY BAR OVERFLOW TUBE GREEN LIGHT SWITCH ON OFF GREEN LIGHT SWITCH ON OFF...

Страница 47: ...lectric Circuit LINE CAMME 4 CAMME 3 CAMME 2 CAPILLARY TUBE CONDENSER PRESSURE SWITCH CONDENSER COMPRESSOR HOT GAS VALVE SUCTION LINE NEUTRAL FAN CAMME 1 TIMER MOTOR EVAPORATOR THERMOSTAT BIN THERMOSTAT WATER INLET VALVE WATER SUPPLY PUMP EVAPORATOR SPRAYERS BAR OVERFLOW PIPE GREEN LIGHT SWITCH ON OFF CONTACTOR CONTACTOR COIL CONTACTOR HP SAFETY PRESSURE SWITCH GREEN LIGHT SWITCH ON OFF ...

Страница 48: ...R CAMME 4 CAMME 3 CAMME 2 CAMME 1 TIMER MOTOR WATER OUTLET PRESSOSTATIC VALVE WATER INLET NEUTRAL SUCTION LINE COMPRESSOR EVAPORATOR THERMOSTAT BIN THERMOSTAT CAPILLARY TUBE WATER INLET WATER INLET VALVE PUMP HOT GAS VALVE EVAPORATOR SPRAYER BAR OVERFLOW PIPE CONTACTOR CONTACTOR COIL CONTACTOR Hydraulic Circuit Refrigerant Circuit Electric Circuit GREEN LIGHT SWITCH ON OFF GREEN LIGHT SWITCH ON OF...

Отзывы: