![Diamond Systems Poseidon Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/diamond-systems/poseidon/poseidon_user-manual_2494418080.webp)
Conversion Formula for Unipolar Input Ranges
Input voltage = (A/D code + 32768) / 65536 * Full-scale input range
Example:
Given, Input range is 0-10V and A/D code is 17761.
Therefore,
Input voltage = (17761 + 32768) / 65536 * 10V = 7.7103V.
For a unipolar input range, 1 LSB = 1/65536 * Full-scale voltage.
The following table illustrates the relationship between A/D code and input voltage for a unipolar input range (VFS
= Full scale input voltage).
A/D Code Input Voltage Symbolic Formula Input Voltage for
0−10
V Range
-32768
0V
0.0000V
-32767
1 LSB (V
FS
/ 65536)
0.153mV
...
...
...
-1
V
FS
/ 2 - 1 LSB
4.99985V
0
V
FS
/ 2
5.0000V
1
V
FS
/ 2 + 1 LSB
5.00015V
...
...
...
32767
V
FS
- 1 LSB
9.9998V
Diamond Systems Corporation
Poseidon User Manual