DiaDent Dia-Gun Скачать руководство пользователя страница 14

15

A. 1 Year Limited Warranty (excluding safety cap, gun tips, plunger, plunger o-rings, power adapter &

cord, multipurpose wrench, and brush).

B. The manufacturer gives a one (1) year warranty effective from the date of purchase. Any defects or

errors that are due to faulty manufacturing or material will be repaired or replaced within this
warranty period.

C. To obtain warranty coverage and to return the device to the manufacturer s service facility, please

contact your sales representative. Products returned for warranty coverage should be securely
packed and shipped with postage prepaid. DiaDent does not accept shipments sent collect.
Manufacturer will be responsible for shipping the repaired or replacement product to you.

D. Manufacturer disclaims liability and is not responsible for repair or replacement of product in the

case of:
- Noncompliance with this instruction manual.
- Operating and/or handling the device without care.
- Damage caused by natural disasters.
- Incorrect diagnosis or poor result due to operator error. 
- Device damages resulting from repairs or modifications not serviced by the manufacturer. 

Item

Codes

Dia-Gun Set

#4001-1001

Handpiece

#4001-1010

Charger

#4001-1020

Safety Cap(2ea)

#4001-1030

Plunger

#4001-1040

Plunger O-rings(4ea)

#4001-1050

Power Adapter & Cord

#4001-1060

Disposable Gun Tips(4ea, 23G)

#4001-1070

Disposable Gun Tips(4ea, 25G)

#4001-1071

Multipurpose Wrench

#4001-1080

Scrubbing Brush

#4001-1090

Battery

#4001-1100

Gutta Percha Obturator(100ea)

#181-101

Содержание Dia-Gun

Страница 1: ...INSTRUCTION M A N U A L Copyright 2009 DiaDent Group International www diadent co kr www diagun co kr C ...

Страница 2: ...04 18 32 Page ...

Страница 3: ...ring On Placing the safety cap Obturating Powering Off 6 Cleaning and Maintenance 14 Cleaning the charger Cleaning the handpiece Cleaning the inside of heat chamber Cleaning the safety cap Cleaning the plunger 7 Disposal 14 Handpiece and charger disposal Battery pack disposal Tips disposal 8 Device Item Codes 15 9 Warranty 15 10 Trouble Shooting 16 11 Technical Specification 17 12 Symbol 17 ...

Страница 4: ... other warnings and cautions throughout this manual Caution s indicates information which if not followed properly could result in serious injury to the patient or the operator and damage the device 1 This device should be used exclusively by trained and qualified dentists and endodontists only If the device is used by any other users that are not specified in this manual the manufacturer has no l...

Страница 5: ...sure you have everything If any item is missing or damaged contact your sales representative 1x Handpiece 1x Charger 2x Safety Caps 1x Plunger Set 4X O rings 1x Power Adapter Cord 4x Disposable Gun Tips 23G 1x Multipurpose Wrench 1x Gutta Percha Obturator 100ea 1x Scrubbing Brush 1x User Manual ...

Страница 6: ...7 ...

Страница 7: ...ve a flow of warm Gutta Percha Obturator F Heat Chamber with safety cap Swivel 360 to adjust needle s direction Soft safety cap can reduce the possibility of injury during use Always steam autoclave the safety cap before use G Disposable gun tips 23G Connect the tip tightly to heat chamber and bend or remove using the multipurpose wrench H Multipurpose Wrench After the needle is placed properly be...

Страница 8: ...uce the injury of patient or operator always place the safety cap on during use 8 Gun tip should be tightened moderately so that there is no leakage or flow out of Gutta Percha Obturator Over tightening the tip may lead to damage to the tip and or handpiece The tip can be adjusted and bent to the desired degree by the supplied wrench Do not bend the needle by force 9 To prevent injury when the gun...

Страница 9: ...ARGER 1 For proper operation the charger must be installed and used in a dry environment If the charger becomes wet unplug and dry it immediately 2 Check the required voltage before connecting the charger to the power adapter Failure to do so may damage the charger and or the handpiece 3 Place the charger on a level and safe surface 4 Use only the power adapter that is supplied by the manufacturer...

Страница 10: ...11 ...

Страница 11: ... back not out of the body to empty the loading slot Then pull down the front of the device until the tip faces downward to insert the pellet into the loading slot After placing the Gutta Percha pellet in the loading slot push it into the heat chamber using the plunger When the pellet is not inserted properly the trigger will not work correctly It is better to operate the trigger in a continuous an...

Страница 12: ...illed in the root canal transfer heat for 3 to 5 seconds Operate the trigger slowly flow the melted Gutta Percha Obturator to the root canal and continue flowing while withdrawing the needle from the canal Use an Endodontic hand plugger to compact obturation material Repeat as needed until canal is filled without voids and take a radiograph G Powering Off Press the power button for one 1 second to...

Страница 13: ...d It would be better to clean handpiece contacts with Alcohol C Cleaning the inside of heat chamber Remove the tip by wrench and clean all visible soil from Gutta Percha Obturator in the heat chamber with scrubbing brush Melt the residual at 160 and clean it all D Cleaning the safety cap After each use steam it using a steam autoclave E Cleaning the plunger Wipe it with a soft cloth dampened with ...

Страница 14: ...ufacturer will be responsible for shipping the repaired or replacement product to you D Manufacturer disclaims liability and is not responsible for repair or replacement of product in the case of Noncompliance with this instruction manual Operating and or handling the device without care Damage caused by natural disasters Incorrect diagnosis or poor result due to operator error Device damages resu...

Страница 15: ...k Check that the charger light is on Check that the power adapter is plugged into power outlet compatible with the voltage Check to see if the charger or power adapter is damaged If charger light is not on please contact your representative Ensure that the handpiece is placed firmly into the charger base If the battery contact points of the handpiece or charger are wet dry immediately and do not u...

Страница 16: ...tting Temperature 160 180 200 C Charging time Approx 2 hrs 30 min Operation time per full charge 20 times per four and half 4 5 min Handpiece 180 x 124 x 33mm W x H x D Dimensions Charger 156 x 65 x 88mm W x H x D Handpiece 186g Weight Charger 305g Adapter 200g Power Supply Adapter Input 100V 240V 50 60 Hz 0 4A Output 5V 2A Battery Li ion Battery DC 3 7V 2200mAh Temperature 10 40 Storage Condition...

Страница 17: ...15 Fax 82 43 262 8658 E mail diadent chollian net DiaDent Group International Inc Canada USA 11 3871 North Fraser Way Burnaby B C Canada V5J 5G6 Tel 1 604 451 8851 Fax 1 604 451 8865 E mail diadent diadent com www diadent com DiaDent Europe B V Europe Antennestraat 70 1322 AS Almere The Netherlands Tel 31 36 549 8607 Fax 31 36 536 7317 E mail diadent diadenteurope com www diadenteurope com ...