DSP-100 User Manual
Page 5 of 25
DSP100_MAN_A
3.
Technical Data
Functional Data
Sensitivity:
Eight sensitivities are user selectable.
Setting
S3
S2
S1
Sensitivity
0
OFF OFF OFF
1.28% -
ΔL/L
1
OFF OFF ON
.64% -
ΔL/L
2
OFF ON OFF
.32% -
ΔL/L
3
OFF ON
ON
.16% -
ΔL/L
4
ON OFF OFF
.08% -
ΔL/L
5
ON OFF ON
.04% -
ΔL/L
6
ON
ON OFF
.02% -
ΔL/L
7
ON
ON
ON
.01% -
ΔL/L
Frequency Settings:
There are four frequency settings available. The actual loop frequency is
dependent on loop circuit inductance.
DIP Switch
Frequency
5
6
OFF
OFF
High
OFF
ON
Medium High
ON
OFF
Medium Low
ON
ON
Low
Response Time:
Response time is dependent on the sensitivity selected.
Setting
Response Time
Setting
Response Time
0
88ms ±12ms
4
88ms ±12ms
1
88ms ±12ms
5
88ms ±12ms
2
88ms ±12ms
6
88ms ±12ms
3
88ms ±12ms
7
176ms ±24ms
Vehicle Hold Time:
Approximately 1 hour for a detection of 1% -
ΔL/L
.
Electrical Data
Loop Inductance:
20 microhenries to 1500 microhenries (including lead-in inductance). Not all
frequency settings are available at inductances below 30 microhenries.
Operating Voltages:
90 volts to 140 volts AC
Output Rating:
Solid-State
Open Collector, 30 mA max, 30 VDC max.
Relay
3A, 150 VDC or 300 VAC
Operating Voltage:
90 to 140 volts AC