A-20
ID-08 / ID-09 High Performance Imager – User´s Manual
Serial Commands
Command Types
#
Causes the reader to beep the specified number of times;
data
contains
the number as a single character in the range [0,127].
(The reader will rdi-soric ID - Softwareond with
d
or
e
.)
Example – beep three times: #%03
$
Posts an event to the reader;
data
contains the event number as a single
character. See setting 39 in
Reader Settings
for a list of the event numbers.
(The reader will rdi-soric ID - Softwareond with
d
or
e
.)
(
Causes the reader to upload any logged error messages (no
data
)
(The reader will rdi-soric ID - Softwareond with a g packet, zero or more
z packets, and a final
d
or
e
. Each
z
packet contains a portion of the
requested data in its
data
field.
Note:
This is very similar to the rdi-soric ID - Softwareonse to the X
command; however,
p
packets are not applicable and the
g
and
d/e
packets are not suppressed even in raw mode.)
)
Causes the reader to erase its log of error messages (no
data
)
(The reader will rdi-soric ID - Softwareond with
d
or
e
.)
,
Causes the reader to send a list of current reader settings (no
data
)
(The reader will rdi-soric ID - Softwareond with d containing a space-
separated list of all setting values (in order, expressed as hexadecimal
ASCII characters) or with
e
.)
/
Toggle a bit (or bits) in a reader setting;
data
contains a printable ASCII
string in the following format: hexadecimal setting number in parenthe-
ses followed by a 32-bit signed integer value, expressed in ASCII hexa-
decimal characters (with optional minus sign) or ASCII decimal
characters preceded by the ‘#’ character, e.g., /(2e)1000 or /(2e)#4096;
the specified integer is XOR’ed with the existing setting value.
(The reader will rdi-soric ID - Softwareond with
d
or
e
.)
Note:
See
Reader Settings
for possible reader settings.
1
Indicates the start of a file download;
data
is empty. This command is
followed by a sequence of
2
commands containing the file data and a
download-end command (e.g.,
5
).
(The reader will rdi-soric ID - Softwareond with
d
or
e
.)
2
Indicates a continuation of a file download;
data
contains the next por-
tion of the file data.
(The reader will not send any rdi-soric ID - Softwareonse.)
5
Indicates the end of a regular file download;
data
contains the name of
the file, which is from 1 to 200 letters, digits, periods, hyphens, and
underscores, terminated with ASCII NUL.
(The reader will rdi-soric ID - Softwareond with
d
,
e
, or
f
.)
Содержание ID-08
Страница 1: ...ID 08 ID 09 Handheld Reader User s Manual ID 08 ID 09 User s Manual ...
Страница 38: ...3 4 ID 08 ID 09 High Performance Imager User s Manual ...
Страница 42: ...3 8 ID 08 ID 09 High Performance Imager User s Manual ...
Страница 58: ...4 16 ID 08 ID 09 High Performance Imager User s Manual Text Command Timeout ...
Страница 70: ...5 12 ID 08 ID 09 High Performance Imager User s Manual ...
Страница 100: ...7 10 ID 08 ID 09 High Performance Imager User s Manual Image Quality ...
Страница 114: ...9 8 ID 08 ID 09 High Performance Imager User s Manual Terminal Dropdown Menu ...