14
DHOLLANDIA
M
•
The mounting height
mfc
is measured from the top of the vehicle bed to the center of the lift arm articulation pin. Look carefully [Figure
7.3] how to measure this dimension on the DH-SM range.
•
In absence of an installation drawings, following simplified methods are sometimes applied:
1.
Mount the bottom of the mounting bracket flush with the bottom of the chassis. [Figure 7.4]
2.
Or, in order to gain more ground clearance: dismount the tooth rack from the slide tube [1 in Figure 7.5]; slide the tube over the
rollers; measure distance X from the top of the slide tube to the top of the gear wheel cross bar [2]; and mount the brackets at a
distance X
–
1.18
”
above the bottom of the chassis [3]. [Figure 7.5]
NOTICE
When determining the mounting height, verify and make sure you comply with the given ranges for the installation parameters
vfh
,
mfc
and
mcg
[Figure 7.1
–
7.2].
Figure 7.3
Figure 7.4
Figure 7.5