WOUND CARE SETS (supplied separately: available in singles and packs of 10)

•  Gauze Wound Care Set
•  Slim Foam Wound Care Set
Note: Other Wound Care Sets may be available; please contact Direct Healthcare Group for latest information.

ALSO AVAILABLE

150ml canister with solidifier; 5V Mains adapter FW7662M/05; Carry bag

3.5 General Warnings, Cautions and Information

•  There are no special skills required to operate the power unit however, Negative Pressure Wound Therapy 

should only be used under the advice, recommendation and supervision of a licensed Physician and / or a 
registered nurse.

•  The medical professional is responsible for applying his/her best medical judgment when using this system. Prior to use, 

the medical professional(s) treating the wound must assess how to best use the system for an individual wound.

•  Select correct setting for therapy required. Care should be taken not to accidently change pressures once set as the 

efficiency of the therapy may be reduced. This could also be caused by pets, pests or children.

•  The electricity supply is of the type indicated on the power adapter.
•  Check the power adapter cord is free from damage and is positioned so as not to cause an obstruction, or injury, e.g. 

strangulation. Do not position the vacuum power unit or power adapter such that makes it difficult to disconnect the 
supply or drain plug.

•  Ensure the power adapter cord, drain tube or vacuum power unit cannot become trapped or crushed, e.g. via raising or 

lowering of bed or bed rails or any other moving object. All tubes must be free of kinks, twists, properly connected and 
positioned so as not to cause an obstruction or injury.

•  Do not place the vacuum power unit or power adapter on or near a heat source.
•  Never use the power adapter whilst placed on top of or near to material which is flammable or can be damaged by heat. 

(The supplied power adapters plug directly into the power source partly mitigating this issue).

•  The 

VENTURI

 MINO TG600/14 vacuum power unit must only be used with the approved power adapter supplied by 

Direct Healthcare Group (see Specification on page 12)

•  The 

VENTURI

 MINO NPWT system (Vacuum power unit and power adapter) is not used in the presence of flammable 

anesthetics or in an oxygen enriched environment.

•  No part of the medical device should be serviced while it is in use by the patient.
•  The medical equipment requires 5 hours to warm from the minimum storage temperature before it is ready for its 

intended use.

•  The medical equipment requires 1 hour to cool from the maximum storage temperature before it is ready for its intended 

use.

•  Electric shock hazard; do not remove back of power unit.
•  Suitable for continuous or intermittent use.
•  Not suitable for sterilisation.
•  The materials used in the manufacture of all components of the system comply with the required fire safety regulations.
•  Direct Healthcare Group advise against smoking whilst the system is in use, to prevent the accidental secondary ignition 

of associated items which may be flammable.

•  WARNING: No modification of this equipment is allowed. Do not use unspecified parts.
•  Choking may result from a child swallowing a small part that has become detached from the ME equipment.
•  A Wound Care Set must be used with the 

VENTURI

 MINO system to carry out NPWT.

•  Please refer to the Wound Care Set ‘Instructions for Use’ leaflet (supplied with Wound Care Set) for dressing application 

and setup. Note that the dressings in the set are sterile and for single patient / single use only, not intended for reuse.

•  Check canister regularly and at each canister change for signs of increased bleeding from the wound.
•  If the wound exhibits swelling, pain, heat or redness of the surrounding skin, check wound for local infection.

D H G - H E A LT H C A R E . C O M

4

V E N T U R I

®

  M I N O

Содержание TG600/14

Страница 1: ...DHG HEALTHC AR E C O M DHG HE ALTHCAR E C O M VENTURI MINO User Manual...

Страница 2: ...VENTURI MINO DHG HEALTHCARE COM...

Страница 3: ...tions and Information 4 4 How to Apply NPWT 5 Getting Started 5 Operating the Vacuum Power Unit 5 5 Operation Guidelines 6 User Information 6 Operation Controls 7 Battery Information 7 6 Care and Main...

Страница 4: ...n Warning Refer to instruction manual booklet Medical Devices Directive 93 42 EEC Medical Device Regulation 2017 745 North America ETL listed Class II Equipment Double Insulated Do not dispose of with...

Страница 5: ...gery Wounds which may benefit from the application of NPWT include pressure ulcers dehisced surgical wounds diabetic neuropathic foot ulcers venous leg ulcers post op surgical wounds including flaps a...

Страница 6: ...near to material which is flammable or can be damaged by heat The supplied power adapters plug directly into the power source partly mitigating this issue The VENTURI MINO TG600 14 vacuum power unit...

Страница 7: ...o the VENTURI MINO power unit by lining up the two parts pushing together and twisting to lock Fig 1 Remove the bung from the connector port this can be retained to cap the used canister prior to disp...

Страница 8: ...ubing as above this can be reconnected to new canister and unclamped if wound dressing is not being changed Rotate canister to unlock and remove from power unit Dispose of used canister according to l...

Страница 9: ...begin operation at the default pressure of 80mmHg The selected vacuum level is shown on the display screen 5 3 Battery Information A fully charged battery should operate the power unit continuously fo...

Страница 10: ...ocial care facilities TECcare CONTROL products provide class leading broad spectrum high level disinfection with an exceptional safety profile Being pH neutral TECcare CONTROL can be universally used...

Страница 11: ...heck that low flow is not caused by pinched or bent tubing If exudate is pooling in the wound bed the dressing should be changed This alert will self cancel after 5 minutes and will re occur if the co...

Страница 12: ...above mains adapter is considered part of the ME equipment The VENTURI MINO power unit must only be used with the specific external power adapter as supplied by Direct Healthcare Group EXPECTED SERVIC...

Страница 13: ...ntinuous resets Try to ascertain the source of the interference by turning nearby or suspect equipment off and see if the interference effects stop In any such event the user is encouraged to try to c...

Страница 14: ...UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 Mains supply quality for the mains adapter should be that of a typical commercial and or hospital environment In the event of a mains interruption the V...

Страница 15: ...rs such as base stations for radio cellular cordless telephones and land mobile radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electroma...

Страница 16: ...et Swatar BKR 4013 Malta Direct Healthcare Group Ltd Withey Court Western Industrial Estate Caerphilly United Kingdom CF83 1BF T 44 0 800 043 0881 F 44 0 845 459 9832 E info directhealthcaregroup com...

Отзывы: