8. Technical Specifications

8.1 VENTURI MINO Power Unit

(Medical Device Classification: Class IIb)
Model Ref.: 

Venturi v.II TG600/14

Construction: 

Flame retardant ABS

Dimensions: 

W112mm/4.4” x H112mm/4.4” x D52mm/2” (with canister fitted)

Weight: 

250 g / 5.5 lbs

DC Input Voltage: 

5V Nominal

Vacuum Application: 

Continuous

Pressure Range: 

80mmHg or 120mmHg (+ / - 5mmHg)

Fixed Internal Battery:  3.7V 11.3mAh Lithium Ion - Rechargeable Cell
IP Rating: 

IP22

Noise Level: 

50 dBa

8.2 Canister 

(ACCESSORY to TG600/14)

Construction: 

ABS, textured (includes absorbant media)

Capacity: 

150 ml

Dimensions: 

W54mm/2.1” x H112mm/4.4” x D52mm/2”

8.3 Power Adapter 

(ACCESSORY to TG600/14)

Mains Adapter Type: 

FW7662M/05 (supplied)

Input: 

100-240V / 50-60Hz / 700mA

Output: 

5V dc / 1.1A

Cable Length: 

2 metres / 6.5’

Part Number: 

10246

The above mains adapter is considered part of the ME equipment.

The 

VENTURI

 MINO power unit must only be used with the specific external power adapter as supplied by Direct 

Healthcare Group.

EXPECTED SERVICE LIFE: The expected service life of the medical device and its ACCESSORIES is two years.

SPECIFIED SHELF LIFE: The product has no specified shelf life.

Products are free from TSE species derived materials, medicinal substances, human blood derivatives and phthalates.

Talley manufacture products to comply with National and International safety standards and are certified to ISO13485, 
Medical Devices Directive 93/42/EEC and Medical Device Regulation 2017/745.

This medical device is compliant with:
IEC 60601.1 3rd edition Medical electrical equipment safety and essential performance
IEC 60601.1.11 Home healthcare environment

8.4 Manufacturer’s Guarantee

The 

VENTURI

 MINO power unit is covered by a 12 month manufacturer’s guarantee.

D H G - H E A LT H C A R E . C O M

1 0

V E N T U R I

®

  M I N O

Содержание TG600/14

Страница 1: ...DHG HEALTHC AR E C O M DHG HE ALTHCAR E C O M VENTURI MINO User Manual...

Страница 2: ...VENTURI MINO DHG HEALTHCARE COM...

Страница 3: ...tions and Information 4 4 How to Apply NPWT 5 Getting Started 5 Operating the Vacuum Power Unit 5 5 Operation Guidelines 6 User Information 6 Operation Controls 7 Battery Information 7 6 Care and Main...

Страница 4: ...n Warning Refer to instruction manual booklet Medical Devices Directive 93 42 EEC Medical Device Regulation 2017 745 North America ETL listed Class II Equipment Double Insulated Do not dispose of with...

Страница 5: ...gery Wounds which may benefit from the application of NPWT include pressure ulcers dehisced surgical wounds diabetic neuropathic foot ulcers venous leg ulcers post op surgical wounds including flaps a...

Страница 6: ...near to material which is flammable or can be damaged by heat The supplied power adapters plug directly into the power source partly mitigating this issue The VENTURI MINO TG600 14 vacuum power unit...

Страница 7: ...o the VENTURI MINO power unit by lining up the two parts pushing together and twisting to lock Fig 1 Remove the bung from the connector port this can be retained to cap the used canister prior to disp...

Страница 8: ...ubing as above this can be reconnected to new canister and unclamped if wound dressing is not being changed Rotate canister to unlock and remove from power unit Dispose of used canister according to l...

Страница 9: ...begin operation at the default pressure of 80mmHg The selected vacuum level is shown on the display screen 5 3 Battery Information A fully charged battery should operate the power unit continuously fo...

Страница 10: ...ocial care facilities TECcare CONTROL products provide class leading broad spectrum high level disinfection with an exceptional safety profile Being pH neutral TECcare CONTROL can be universally used...

Страница 11: ...heck that low flow is not caused by pinched or bent tubing If exudate is pooling in the wound bed the dressing should be changed This alert will self cancel after 5 minutes and will re occur if the co...

Страница 12: ...above mains adapter is considered part of the ME equipment The VENTURI MINO power unit must only be used with the specific external power adapter as supplied by Direct Healthcare Group EXPECTED SERVIC...

Страница 13: ...ntinuous resets Try to ascertain the source of the interference by turning nearby or suspect equipment off and see if the interference effects stop In any such event the user is encouraged to try to c...

Страница 14: ...UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 Mains supply quality for the mains adapter should be that of a typical commercial and or hospital environment In the event of a mains interruption the V...

Страница 15: ...rs such as base stations for radio cellular cordless telephones and land mobile radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electroma...

Страница 16: ...et Swatar BKR 4013 Malta Direct Healthcare Group Ltd Withey Court Western Industrial Estate Caerphilly United Kingdom CF83 1BF T 44 0 800 043 0881 F 44 0 845 459 9832 E info directhealthcaregroup com...

Отзывы: