7.1.5
Linked 52/MB at a MADI Port
If a MADI port was linked to an 52/MB MADI Breakout System, you are able to define the layout of the connected 52/MB
device here. Basically, this part of the configuration is to make the whole configuration process easier. The 52/MB
hardware itself must not be configured.
I/O configuration of a linked 52/MB.
The following modules can be configured in an 52/MB frame:
Slots 1 to 14:
·
52-5111 XLR Digital In/Out Module, 4ch.
·
52-5112 XLR Digital In/Out Module, 4ch.
·
52-5170 (4in/4out or 8in or 8out) HD-SDI Audio Module
·
52-5210 XLR Analog In Module, 4ch.
·
52-5213 XLR Analog In Module, 4ch.
·
52-5220 XLR Analog Out Module, 4ch.
·
52-5223 XLR Analog Out Module, 4ch.
·
52-5230 XLR and Combined XLR/Jack Socket Analog In/Out Module, 2ch.
·
52-5240 XLR Analog In/Out Module, 4ch.
·
52-5243 XLR Analog In/Out Module, 4ch.
·
52-5250 XLR 4 Mic/Line Module, isolated
·
52-5260 XLR 4 Line Out Module, isolated
Slots C1 to C5:
·
52-5310 SubD GPIO Module, 8 out, 4 in
·
52-5311 SubD GPIO Module, 8 out, 4 in
The channels of the selected I/O modules can be configured to mono or stereo and you can set a label for each single
input and output here. Additionally, you can set a local level adjustment for each single input and output.
Moreover, you can adjust the headroom for the inputs of the 52-5230 and 52-5250 modules. Please note, that these
settings influence the internal reference level (
0 dBint
) you select in the
Level Adjust
column. If you change the
headroom of an 52-5230 or 52-5250 module and use the function
Set all analog level
afterwards, may be some