4
www.df-models.com
INTRODUCTION
Thank you for purchasing the new I-Peak 6 Charger. This product is a rapid charger with a high
performance microprocessor and specialized operating software. Please read this entire operat-
ing manual completely and attentively before using this product, as it covers a wide range of
information on operating and safety.
Speci
fi
cations
Operating voltage range:
DC 11.0 ~ 18.0V
AC in: 100 ~ 240V • 50/60Hz
Circuit power:
Max. charge power 50W
Max. discharge power 5W
Charge current range:
0.1 ~ 6.0A
Current drain for balancing Li-Po:
300mAh/cell
NiCd/NiMH battery cell count:
1~15 cells
Li-ion/Polymer cell count:
1~6 series
Gel cell battery voltage:
2V ~ 20V
Weight: 433g (Net Weight)
Dimensions:
135 x 112 x 61mm
Special features
Optimal operating software
I-Peak 6 features the so-called AUTO function that set the feeding current during the process of
charging or discharging. Especially for Lithium batteries, it can prevent the overcharging which
may lead to an explosion due to the user’s fault. It can disconnect the circuit automatically and
alarm once detecting any malfunction. All the programs of this product were controlled through
two way linkage and communication, to achieve the maximum safety and minimize the trouble.
All the settings can be confi gured by users!
Internal independent lithium battery balancer
I-Peak 6 employs an individual-cell-voltage balancer. It isn’t necessary to connect an external
balancer for balance charging.
Balancing individual cells battery discharging
During the process of discharging, I-Peak 6 can monitor and balance each cell of the battery
individually. Error message will be indicated and the process will be ended automatically if the
voltage of any single one cell is abnormal.
Adaptable to various type of lithium battery
I-Peak 6 is adaptable to various types of Lithium batteries, such as Li-ion, LiPo and the new LiFe
series of batteries.
Fast and storage mode of lithium battery
Purposes to charge Lithium battery varies, ‘fast’ charge reduce the duration of charging, whereas
‘store’ state can control the fi nal voltage of your battery, so as to store for a long time and protect
useful time of the battery.
Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the principle of the
Delta-peak voltage detection. When the battery’s voltage exceeds the
threshold, the process will be terminated automatically.
Automatic charging current limit: You can set up the upper limit of the charging current when
charging your NiCd or NiMH battery; it is useful for the NiMH battery of
low impedance and capacity in the ‘AUTO’ charging mode.