13
www.df-models.com
Li3s
0.4A 12.59V
DSC
022:43 00682
Number of cells
Charging current
Battery voltage
Elapsed time
Discharged capacity
Voltage balancing and monitoring in the discharge process
The processor monitors voltage of each cell when the battery packs are during its “storage”
and “discharging” process. To achieve this feature, plug each battery to the charger individually.
If voltage of any cell is abnormal, I-Peak 6 will show error message and terminate the program
forcibly. So if there is battery damage or disconnection, you can see the error message and press
”INC” to know which cell is damaged.
BATTERY VOL ERR
CELL
LOW VOL
The processor detects voltage of one cell is too low.
4.14 4.16 4.09
2.18 0.00 0.00
The 4th cell was damaged. The value of voltage may be zero if disconnection occurs.
PB LEAD-SULPHURIC ACID BATTERY PROGRAM
• This program is only suitable for charging Pb lead-acid battery with nominal voltage from 2 to
20V.
Pb lead-acid battery is completely different from NiCd/NiMH battery. These batteries can only
deliver current lower in comparison to their capacity. The same restriction applies to the charging
process. Consequently, the optimum charge current can only be 1/10 of the capacity.
Pb battery cannot be used for fast-charging, please follow the instructions provided by the bat-
tery manufacturer. You can press “Start/Enter” key to make it blink and alter the value of param-
eters using ”INC”or”DEC” key, press “Start/Enter” key to store the value.
Charging of the Pb battery
Set up the charge current on the left and nominal voltage on the right. Range of current is 0.1-
5.0A, the voltage should match the battery being charged. Press “Start/Enter” key for more than
3 seconds to start charging.
Pb
CHARGE
4.0A
12.0V(6P)
The screen displays the real-time discharging status. Press “Start/Enter” key to alter discharge