- 25 -
System Param
Param
<<
Run
Pic 7.9 Limit switch
4. Operate the button [up down], move setting cursor to limit function and press the
button [enter] .At this time you can turn on or turn off the limit function by choosing
[up down] button, please press [enter] button to confirm when setting done.
5. Move the cursor to [confirm] , press ENTER to save the settings and exit the running
parameters page, otherwise the settings are invalid.
6.Need to understand that [grid power] shows positive means grid power is consuming
energy, and there is no backflow.If [grid power] is negative, it means backflowr to the
grid or current transformer direction error has occurred.Please read more on chapter 7.9.
7. After properly connection is done, wait for inverter starting, If the power of the PV
array meets the current power consumption, the inverter will maintain a certain output
to counteract the power of the grid without backflow .
Fun GFDI OFF
OFF
<<
Limiter
_
Pic7.8 Parameter setting