- 37 -
11.Specification
Model
Max.DC Power(kW)
Max.DC Input Voltage(V)
Start-up DC Input Voltage(V)
Number of MPPT/
Strings per MPPT
MPPT Operating Range(V)
Max.DC Input Current(A)
Rated Output Power(kW)
SUN-12K-G03
SUN-15K-G03
SUN-18K-G03
1000
250
200~800
2/2+2
2/1+2
2/1+2
10+20
10+20
20+20
12
15
18
15.6
18
21.6
Topology
Transformerless
Weight(kg)
Internal consumption
17
<1W(Night)
Max.Active Power(kW)
Rated AC Grid Voltage(V)
AC Grid Voltage Range(V)
Rated Grid Frequency(Hz)
Operating Phase
Rated AC Grid Output Current(A)
Max.AC Output Current(A)
Grid Current THD
DC Injection Current(mA)
Output Power Factor
>0.99
<3%
<0.5%
Grid Frequency Range
Max.Efficiency
Euro Efficiency
MPPT Efficiency
Protection
Size(mm)
13.2
16.5
19.8
380/400
277~460
50/60(Optional)
Three phase
17.4
19.14
DC reverse-polarity protection;AC short circuit protection;AC output
overcurrent protection;Output overvoltage protection;Insulation resistance
protection;Ground fault monitoring;Surge protection;Islanding protection;
Temperature protection;Integrated DC Switch (Optional);
47-52 or 57-62(optional)
97.5%
>99%
330W×430H×193.5D
21.8
26.1
24
28.71
98.5%
Ingress protection
Operating temperature
-25 ~ 60℃
Noise Emission(Typical)
IP65
<30dB