Page 25
Printing version 2.6
•JUL2017
Quarter bridge 10V excitation:
Sensor
3-wire sensor connection
Connector
Exc+
IN+
Sense+
IN-
2
1
7
Sense-
Exc-
6
3
8
SHD
GND
4
Note: Bridge completion needs to be done in the connector.
Full bridge 5V excitation:
The excitation level between EXC+ and EXC- is 10 V. If lower excitation (5V) is
needed, please connect the GND pin instead of EXC- to negative sensor supply.
Sensor
5V bridge sensor connection
Connector
Exc+
IN+
Sense+
IN-
2
1
7
GND
6
4
SHD