SAFETY INSTRUCTIONS
FOR TOOL OPERATION
Always handle the tool with care:
l
Never engage in horseplay;
l
Never pull the trigger unless the nose is directed
towards the work.
l
Keep others at a safe distance from the tool while the
tool is in operation, as accidental actuation may occur,
possibly causing injury.
l
The operator must not hold the trigger pulled on safety
trip tools except during fastening operation, as serious
injury could result if the trip accidentally contacts
someone or something, causing the tool to cycle.
l
Keep hands and body away from the discharge area of
the tool. A safety trip tool may bounce from the recoil
of driving a fastener and an unwanted second fastener
may be driven possibly causing injury.
l
Check operation of the safety trip mechanism
frequently. Do not use the tool if the contact arm is not
working correctly, as accidental driving of a fastener
may result. Do not interfere with the proper operation
of the safety trip mechanism.
l
Do not drive fasteners on top of other fasteners as
this may cause deflection of the fastener, which could
cause injury.
l
Do not drive fasteners close to the edge of the work
piece as the wood may split allowing the fastener to be
deflected, possibly causing injury.
SAFETY INSTRUCTIONS
FOR TOOL MAINTENANCE
When working on gas tools, pay attention to the warnings in
this manual and on the tool itself and use extra care when
evaluating problem tools.
To prevent accidental actuation and possible injury, always
disconnect the battery and fuel cell:
1.
Before making adjustments.
2.
When servicing the tool.
3.
When clearing a jam.
4.
When tool is not in use.
5.
When moving to a different work area, as accidental
actuation may occur, possibly causing injury.
Check that the tool is functioning correctly by applying the
nose to a piece of scrap wood and pulling the trigger once
or twice.
Tool operation
PREPARATION PRIOR TO OPERATION
MAX
120ºF
(50ºC)
Protect from sunlight. do not store
in vehicles. do not expose to
temaratures higher than 50ºc.
2
DANGER. EXTREMELY FLAMMABLE GAS.
Keep away from heat/sparks/open flames/
hot surfaces.-NO SMOKING. Leaking gas
fire: Do not extinguish, unless leak can be stopped safely.
Store in well-ventilated place.
DO NOT PIERCE.
READ OPERATION INSTRUCTIONS BEFORE USE.
Do not store the tool, fuel cell and battery in a cold weather
environment. Keep the tool, fuel cell and battery in a warm
area until beginning the work.
l
If the tool, fuel cell and battery are already cold, bring
them in to a warm area and allow them to warm up before
use.
l
Observe the temperature limit of 50°C (120°F).
l
Do not expose to an open flame and sparks.
l
This tool may not drive completely when;
- at low temperature, the fuel cell loses the required
propellant force,
- high temperature can affect the performance of the tool .
l
Do not use the tool in the rain or where excessive
moisture is present.
l
This tool is not recommended for use at altitudes above
1500m (5000ft), or in temperatures below 0°C (30°F).
1. FUEL CELL
To attach the metering valve to a fuel cell:
1.
Separate the metering valve and the cap from the gas
cartridge (Fig. 3a).
2.
Press forwards (stem side) and then downwards on the
front side of the metering valve (Fig. 3b).
3.
Press downwards on the rear of the metering valve until
it seals (Fig. 3c).