English
8
Blow Tube Assembly (Fig. D)
1. To attach the tube to the blower, line up the pegs
7
on
the bottom of the tube with the notch
8
on the bottom
of the housing opening as shown in fig. D.
2. Push the tube into the blower housing until the lock
engages the tube.
3. Pull on the tube to ensure it is securely in place.
4. To remove the tube, insert a screwdriver into the
unlocking hole
9
on the side of the blower tube.
Depress the tab inside and pull tube off.
Fig. D
7
8
9
OPERATION
WARNING:
Do not operate blower
without tube securely in place. Never reach down into
housing through tube hole.
WARNING:
Always remove the battery
when you leave blower unattended or when storing,
checking, adjusting, cleaning, or working on blower.
Installing and Removing the Battery Pack
(Fig. E, F)
nOTE:
For best results, make sure your battery pack is
fully charged.
WARNING:
Before removing or installing
battery, make certain the speed lock lever
2
is in the
off position to prevent switch actuation.
To install battery pack:
Insert battery pack
10
into battery
housing
6
as shown in fig. E until fully seated and an
audible click is heard. Make sure battery pack is fully seated
and fully latched into position.
To remove battery pack:
Depress the battery release
button
11
in the top of the battery housing and pull
battery pack out of appliance.
fig. E
6
10
11
Proper Hand Position (Fig. A, E)
WARNING:
To reduce the risk of serious
personal injury,
ALWAYS
use proper hand position
as shown.
WARNING:
To reduce the risk of serious
personal injury,
ALWAYS
hold securely in anticipation
of a sudden reaction.
Hold the blower with one hand on the main handle
4
Fig. E
4
OPERATION
WARNING:
Do not operate blower
without blow tube securely in place. Never reach down
into housing through tube hole.
WARNING:
Always wear safety
glasses. Wear a filter mask if the operation is dusty.
Use of rubber gloves and substantial footwear is
recommended when working outdoors. Keep long hair
and loose clothing away from openings and moving
parts.
WARNING:
Cut Hazard. When turning
the tool off, wait 10 seconds for the fan to stop
rotating before removing the blower tube.
• Always ensure the blower is switched OFF and the
battery is removed when:
-
You leave blower unattended.
-
Clearing a blockage.
-
Checking, adjusting, cleaning or working on blower.
• Only use blower in daylight or good artificial light.