Transporting
When transporting the compressor in a vehicle,
A
C
trailer, etc. ensure that the air tank is drained and
the unit is secured and placed on a flat horizontal
surface. Use care when driving so to avoid
tipping the unit over in the vehicle. Damage can
occur to the unit or surrounding items if unit is
tipped.
Store compressor in a vertical or horzitional position.
lIFtInG
Always use two people when lifting and lift from the recommended
lift points A and C.
MOVInG
1. Support compressor and pull handle (A) until fully extended (lock
position).
A
A
WARNING:
Risk of unsafe operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
2. To move, roll compressor on tires using handle (A) as shown.
PrEPArATION FOr uSE
Pre-Start Checklist (Fig. 1)
1. Ensure the On/Auto/Off switch (L) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection
under
Installation
.
3. Ensure air tank is drained, see
Draining Air tank
under
Maintenance.
4. Ensure the drain valve (B) is closed.
5. Ensure safety valve (G) is functioning properly, see
Checking
safety Valve
under
Maintenance.
6. Pull the regulator knob (F) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 PSI. Push knob
in to lock in place.
7
. Attach hose and accessories.
nOte:
Always use a mini-
mum 3/8" (9.5 mm) or greater air hose rated at 300 PSI.
WARNING:
Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
WARNING:
Risk of unsafe operation. Do not use damaged or worn
accessories.
WARNING:
Risk of Bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
Initial Set-up (Fig. 1)
WARNING:
Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
BreAk-In PrOCeDure
CAUTION:
Risk of unsafe operation.
Do not operate in vertical
position. Vertical position is for storage only.
CAUTION:
Risk of property damage. Serious damage may result if
the following break-in instructions are not closely followed.
This procedure is required
before
the air compressor is put into
service for the first time and when the check valve or a compressor
pump/motor has been replaced.
1. Ensure the On/Auto/Off switch (L) is in the OFF position.