23
English
CODE
POSSIBLE CAUSE
POSSIBLE SOLUTION
10
Hole in air hose
Replace air hose.
11
Check valve restricted
Remove, clean or replace.
12
Air leaks
Tighten fittings.
13
Regulator is damaged
Replace.
14
Unit operating in damp or humid conditions
Move unit to a dry well ventilated area
15
Restricted air intake filter
Clean or replace air intake filter
16
Engine or pump oil is low
Add same type of oil in crankcase to pump. See
Compressor Pump Oil
under
Maintenance.
17
Carbon build-up in pump.
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
18
Detergent type oil being used in pump
Drain oil and refill pump using DeWALT synthetic or SAE
40, non-detergent air compressor oil.
19
Motor overload protection switch has tripped
See
Motor Overload
under
Features
.
20
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. See
Extension Cords
under
Installation
.
21
Loose electrical connections
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
22
Possible defective motor or starting capacitor
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
23
Paint spray on internal motor parts
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center. Do not operate the compressor
in the paint spray area. See flammable vapor warning.