16
English
1.
Ensure the On/Off switch (A) is in the OFF position.
NOTE:
If hose is not connected to Quick Connect body, pull cou-
pler back until it clicks to prevent air from escaping through the
quick connect.
2. Plug the power cord into the correct branch circuit receptacle.
See
Voltage and Circuit Protection
under
Installation
.
3. Open the drain valve (counter-clockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during
the break-in period.
4.
Move the On/Off switch to the ON position.
The compressor will
start.
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valve by turning clockwise.
The tank will fill to
cut-out
pressure and the motor will stop.
7. Compressed air will be available until it is used or bled off.
OPERATING PROCEDURES
Start-up (Fig. 1)
1. Follow
Pre-Start Checklist
under
Preparation for Use
.
2. Move the On/Off switch to the ON position
and allow tank pres-
sure to build. Motor will stop when tank pressure reaches
cut-out
pressure.
CAUTION:
Risk of unsafe operation. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air
op er ated tools or de vic es may require filtered air. Read the in struc-
tions for the air tool or device.
3. Adjust regulator (D) to desired setting. See
Regulator
under
Features.
Shut-down (Fig. 1)
1 Move
On/Off switch (A) is in the OFF position
.
NOTE:
If finished
using compressor, follow Steps 2 - 6.
2. Turn regulator knob (D) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank, see
Draining Air Tank
under
Maintenance
.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING:
Risk of bursting.
Drain air tank daily. Water will condense
in air tank. If not drained, water will corrode and weaken the air tank caus-
ing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure
On/Off switch is in the OFF position
.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE:
All compressed air systems contain maintenance parts
(e.g., oil, filters, separators) that are periodically replaced. These
used parts may contain substances that are regulated and must be
disposed of in accordance with local, state, and federal laws and
regulations.
NOTE:
Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE:
Any service operations not included in this section should
be performed by a D
e
WALT factory service center or a D
e
WALT
authorized service center.