ElectroVap®
ELMC-SB
38
5.5
DEFAULT MESSAGE
Meaning:
The signal passing through the contactor is OFF when it should be ON. The contactor no longer works and there is no
steam production.
In this
case:
When this message appears, the cylinder is drained, the general fault contact is activated, and the unit is then stopped.
Causes and
remedies
:
1.
Check the F1 (2A) fuse on the main map.
2.
Check the connection of the connector wires of the contactor
3.
Make sure the X01 (wire 12 and 13) is well connected to the map
4.
Change the faulty contactor
Meaning:
The signal passing through the contactor is ON when it should be OFF. The contactor has a defect and produces steam
when it should not.
CAUTION : switch the steam generator off before any handling
In this
case:
When this message appears, the cylinder is drained, the general fault contact is activated, and the unit is then stopped.
Causes and remedies:
1.
Turn off the device
2.
Check the condition of the contactors visually
3.
Make sure the X01 (wire 12 and 13) is well connected to the main board
4.
Change the faulty contactor
Meaning:
The water inlet valve is defective, the high level is not reached after 20 minutes.
In this case:
When this message appears, the cylinder is drained, the general fault contact is activated, and the device is not
stopped.
Causes and remedies:
1.
Make sure the water supply faucet is open
2.
Check for water in the cylinder
3.
Change the water inlet valve
Alarm
P1
INFORMATION "CONTACTOR COIL FAILURE"
Alarm
P2
INFORMATION "CONTACTOR BLOCKED"
Alarm
P3
INFORMATION "WATER INLET VALVE"
Содержание ElectroVap ELMC 20-30 SB
Страница 1: ...STEAM GENERATOR FOR STEAM ROOM ElectroVap ELMC SB Series Instruction Operation Manual ...
Страница 25: ...ElectroVap ELMC SB 25 3 8 6 Wiring diagrams ELMC 5 to 10 Up V 1x200 240V 50 60Hz ...
Страница 26: ...ElectroVap ELMC SB 26 ELMC 5 to 30 Up V 3x200 690V 50 60Hz ...
Страница 27: ...ElectroVap ELMC SB 27 ELMC 40 to 60 Up V 3x200 690V 50 60Hz ...
Страница 28: ...ElectroVap ELMC SB 28 ELMC 90 Up V 3x200 690V 50 60Hz ...
Страница 29: ...ElectroVap ELMC SB 29 3 9 OPTION Transformer connection ...
Страница 51: ...ElectroVap ELMC SB 51 ...