ElectroVap®
ELMC-SB
16
3.6
TEMPERATURE SENSOR POSITIONING
The temperature sensor monitors the temperature inside the steam room, and this information is then sent to the
steam generator.
Mounting
- Drill a hole of Ø 25mm in your wall
- Insert the cable in the hole and from the inside of the hammam.
- Mark and drill the 3 holes opposite, put in the dowels.
- Make a silicone seal between the Ø 60mm washer and the wall, then fix the temperature sensor with 3 screws.
- To avoid a possible steam leakage, you can fill the hole of the cable passage with silicone.
Positioning
If you fix the temperature sensor to the ceiling of your
steam room, it is possible to have a slight water
retention at the end of the white strainer of the
sensor. In this case we advise you to cut the end of
the strainer.
Part to cut
Recommended installation
Exceptional installation