User Manual DEV 1953
Copyright DEV Systemtechnik GmbH 2015-2017
55
Note:
If the members of a group are not in the same switching position, two types of
circles are displayed. In this situation the
button is disabled (grayed
out):
To (re-)enable in this scenario the
button (thus Simultaneous
switching mode) either the second,
or
the first and the third switch module
have to be switched via their switch panels (here assuming that all members of
"
Group 2
" are already in the same switching position).
Note that the switching via Web Interface can be performed only if the device
is in Local Mode and that the switching via a group panel is possible only if the
device is in Simultaneous switching mode.
If the device is in Simultaneous switching mode, it is possible to switch the
group either via the corresponding group panel or via one of the Switch panels
of any member of the group.
If the device is in Remote Mode or in Auto Mode, the
and the
switching mode buttons are disabled (grayed out).