3.2.3
DEV 11-0031
DPST Switch Module with Monitor Port; 47...1006 MHz; 75 Ohm, BNC (f)
M o n ito r
In A
In B
O u t
1
4
3
2
In B
M o n ito r
O u t
In A
D E V 1 1 -0 0 3 1
The output port ("
Out
") can be switched to one of two input ports ("
In A
", "
In B
"). The
unused input port is terminated internally. The transmission is DC blocked. Failsafe
relays are used for switching. In the case of power loss, the primary input port
("
In A
") is routed to the output port. For measurement purposes, the monitoring
output port ("
Monitor
") is available.
3.2.4
DEV 11-0034
DPST Sensing Switch Module; DC, 47...1006 MHz; 75 Ohm, F (f)
O u t
In A
In B
L o g ic
E x te rn a l
C o n tro lle r
2
3
1
In A
O u t
In B
D E V 1 1 -0 0 3 4
The functionality of the module DEV 11-0034 is identical with the module
DEV 11-0014 (please refer to chapter 3.2.1), but the module is designed for a
different frequency range and for 75 Ohm with F connectors (instead of 50 Ohm
with SMA connectors).