Seal supply and return air ducts; 

l. 

The vent system 

MUST

 be checked to determine that it is the 

correct type and size; 

m.  Install correct filter type and size; 

n. Unit 

MUST

 be installed so electrical components are protected 

from direct contact with water. 

 
 

1.2.1) Safety 

Rules 

 
Your unit is built to provide many years of safe and dependable 
service providing it is properly installed and maintained. However, 
abuse and/or improper use can shorten the life of the unit and create 
hazards for you, the owner. 
 
a. 

The U.S. Consumer Product Safety Commission recommends 
that users of oil-burning appliances install carbon monoxide 
detectors. There can be various sources of carbon monoxide in a 
building or dwelling. The sources could be gas-fired clothes 
dryers, gas cooking stoves, water heaters, furnaces, gas-fired 
fireplaces, wood fireplaces, and several other items. Carbon 
monoxide can cause serious bodily injury and/or death. 
Therefore, to help alert people to potentially dangerous carbon 
monoxide levels, you should have carbon monoxide detectors 
listed by a nationally recognized agency (e.g. Underwriters 
Laboratories or International Approval Services) installed and 
maintained in the building or dwelling (see Note below). 

 
b. 

There can be numerous sources of fire or smoke in a building or 
dwelling. Fire or smoke can cause serious bodily injury, death, 
and/or property damage. Therefore, in order to alert people to 
potentially dangerous fire or smoke, you should have fire and 
smoke detectors listed by Underwriters Laboratories installed 
and maintained in the building or dwelling (see Note below). 

 
 

NOTE:

 The manufacturer of your furnace does not test any detectors 

and makes no representations regarding any brand or type of 
detector. 

 

 
 

CAUTION 

Ensure that the area around the combustion air intake 
terminal is free of snow, ice and debris

 
 

1.2.2)  Freezing temperatures and your building 

 
 

WARNING 

 

Freezing temperature warning. 

 

Turn off water supply. 

 

If your heater remains shut off during cold weather 
the water pipes could freeze and burst, resulting in 
serious water damage. 

 

 

Your unit is equipped with safety devices that may keep it from 
operating if sensors detect abnormal conditions such as clogged 
exhaust flues. 
 
If the structure is unattended during cold weather you should take 
these precautions : 

a. 

Turn off main water supply into the structure and drain the water 
lines if possible. Open faucets in appropriate areas; 

b.  Have someone check the structure frequently during cold 

weather to make sure it is warm enough to prevent pipes from 
freezing. Contact a qualified service agency, if required. 

 
 

1.2.3) Installation 

regulations 

 
All local and national code requirements governing the installation of 
oil burning equipment, wiring and flue connections MUST be followed. 
Some of the codes that may be applicable are :  
 
CSA 

B139 

INSTALLATION CODE FOR OIL 
BURNING EQUIPMENT 

NFPA 

31 

INSTALLATION OF OIL BURNING 
EQUIPMENT 

ANSI/NFPA 

90B 

WARM AIR HEATING AND AIR 
CONDITIONING SYSTEMS 

ANSI/NFPA 70 

 

NATIONAL ELECTRICAL CODE 

CSA C22.1 

 

CANADIAN ELECTRICAL CODE 

 
Only the latest issues of the above codes should be used. 
 
 

1.3) 

POSITIONING THE FURNACE 

 
The unit must be installed in a location where the ambient and return 
air temperatures are over 15°C (60°F). 
 

CAUTION 

Carefully check your furnace upon delivery for any 
evidence of damage that may have occurred during 
shipping and handling. Any claims for damages or lost 
parts must be made with the Transport Company. 

 
 
This furnace is approved for reduced clearances to combustible 
construction. Therefore, it may be installed in a closet or similar 
enclosure. In any case, the unit must always be installed level. 
 
In a basement, or when installed on the floor, as in a crawlspace, it is 
recommended that the unit be installed on a concrete pad that is 25.4 
to 50.8 mm (1" to 2") thick. 
 

The required minimum clearances for this furnace are specified 
in Table 1. 

Содержание AMT300B34-SM1PMB OLR210F19C

Страница 1: ...stries Inc Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN Use the information in this manual for the installation servicing of t...

Страница 2: ...low all instructions in this manual can result in personal injury and or death property damage furnace malfunction WARNING Fire hazard The furnace must be installed in a level position never where it...

Страница 3: ...Freezing temperatures and your building WARNING Freezing temperature warning Turn off water supply If your heater remains shut off during cold weather the water pipes could freeze and burst resulting...

Страница 4: ...xide gas hazard Never install a hand operated damper in the vent pipe However any Underwriters Laboratories listed electrically operated automatic type vent damper may be installed if desired Be sure...

Страница 5: ...ration into the home Home air exhausters are common Bathroom and kitchen fans power vented clothes dryers and water heaters all tend to create negative pressure in the home Should this occur the chimn...

Страница 6: ...the fuel supply system Fuel Specifications NOTE Use No 1 or No 2 Heating Oil ASTM D396 or in Canada use No 1 or No 2 Furnace Oil Before starting the burner be sure the fuel tank is filled with clean o...

Страница 7: ...m 5 must be allowed between the bottom of the coil drain pan and the top of the heat exchanger Failure to properly seal ducts can result in death personal injury and or property damage The wiring show...

Страница 8: ...pump Fire the burner Adjust the oil pressure as indicated in Table 2 2 2 2 Restart after burner failure 1 Set thermostat lower than the room temperature 2 Press the reset button on the burner primary...

Страница 9: ...urpose of the following test is to check that the electrical outlet on the furnace designated to the BVSO is functional 1 Start up the burner 2 Remove the three pole plug from the BVSO outlet on the f...

Страница 10: ...e unit 8 After cleaning replace the radiator baffles flue collar plate and oil burner 9 Readjust burner for proper operation Soot will have collected in the first sections of the heat exchanger only i...

Страница 11: ...phone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lb psi Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature 0 F Ambie...

Страница 12: ...40 Nozzle Delavan 1 00 70W 1 10 70W 1 25 70W Pump pressure PSIG 145 150 145 Combustion air adjustment turbulator damper 2 5 2 4 2 4 4 AFUE From CSA B21 2 standard and Canadian regulation 86 7 85 4 84...

Страница 13: ...FIGURE 3 14 Model AMT300B34 SM1PMB OLR210F19C DNS 0805 Rev C...

Страница 14: ...15 FIGURE 4 Wiring diagram AMT300B34 SM1PMB OLR210F19C heating only DNS 1017 Rev A...

Страница 15: ...16 FIGURE 4 1 Wiring diagram AMT300B34 SM1PMB OLR210F19C heating and cooling option DNS 1019 Rev A...

Страница 16: ...17 FIGURE 4 2 Ladder diagram AMT300B34 SM1PMB OLR210F19C DNS 1020 Rev A...

Страница 17: ...Rear door assembly 22 Z99F050 Recessed handle black 23 F07O001 Hexagon nut 3 8 16NC brass 24 B02753 Smoke box assembly 25 B02738 Gasket smoke box ITEM PART DESCRIPTION 26 B03349 01 Rear top panel 27 B...

Страница 18: ...on Inc Attention Ne pas alt rer votre unit ou ses contr les Appeler un technicien qualifi INSTALLATEUR TECHNICIEN Utiliser les renseignements dans ce manuel pour l installation et l entretien de l app...

Страница 19: ...ts contenus dans ce manuel s adressent un technicien qualifi exp riment dans ce type de travail au courant des pr cautions prendre des r gles de s curit respecter et muni des outils appropri s ainsi q...

Страница 20: ...iez vous procurer des extincteurs et faire installer dans votre difice ou r sidence des d tecteurs de fum e autoris s par une agence reconnue sur le plan national comme Underwriters Laboratories et le...

Страница 21: ...monoxyde de carbone de feu et d explosion Lire et suivre attentivement les instructions dans la partie suivante Si l vacuation de cette fournaise ou d autres appareils ne sont pas ad quats cela peut p...

Страница 22: ...Elle doit d passer d au moins 0 6 m 2 toute partie d difice se situant dans un rayon horizontal de 3 0 m 10 de la chemin e Elle doit se prolonger d au moins 1 5 m 5 au dessus de la derni re bride fum...

Страница 23: ...leur est de la s rie R7184 de Honeywell NE JAMAIS utiliser la fonction d allumage ignition interrompue V rification de la polarit Les br leurs au mazout utilis s avec les appareils de chauffage centr...

Страница 24: ...1 Air climatis Un climatiseur peut tre install sur l alimentation d air seulement De plus un espace minimum de 127 0 mm 5 est requis entre le dessous du serpentin de climatisation et le dessus de l ch...

Страница 25: ...our l ajustement de l appareil Effectuer les ajustements selon les sp cifications techniques contenues dans ce manuel 2 2 2 D marrage apr s d faillance du br leur 1 Ajuster le thermostat en bas de la...

Страница 26: ...rantie 2 2 7 V rification du dispositif d arr t anti refoulement BVSO Cette v rification sert valider le bon fonctionnement de la prise BVSO sur l unit de chauffage seulement 1 Faire fonctionner le br...

Страница 27: ...central 6 Nettoyer les tuyaux secondaires et le cylindre principal l aide d une brosse rigide et d un aspirateur 7 Avant le r assemblage inspecter l changeur de chaleur et la chambre de combustion afi...

Страница 28: ...technicien de service R SULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po 2 Ajustements du br leur Bande principale Bande fine Position de la t te CO2 Indice de fum e Bacharach Temp rature des...

Страница 29: ...0 Gicleur Delavan 1 00 70W 1 10 70W 1 25 70W Pression de la pompe PSIG 145 150 145 Ajustement air combustion turbulateur volet 2 5 2 4 2 4 4 AFUE partir du standard CSA B212 et des lois canadiennes 86...

Страница 30: ...14 FIGURE 3 Mod le AMT300B34 SM1PMB OLR210F19C DNS 0805 Rev C...

Страница 31: ...15 FIGURE 4 Diagramme lectrique AMT300B34 SM1PMB OLR210F19C chauffage seulement DNS 1017 Rev A...

Страница 32: ...16 FIGURE 4 1 Diagramme lectrique AMT300B34 SM1PMB OLR210F19C chauffage et option climatisation DNS 1019 Rev A...

Страница 33: ...17 FIGURE 4 2 Diagramme en chelle AMT300B34 SM1PMB OLR210F19C DNS 1020 Rev A...

Страница 34: ...23 F07O001 ECROU HEXAGONAL A BRIDE 3 8 16NC LAITON 24 B02753 ASS SORTIE A FUMEE 25 B02738 GARNITURE SORTIE A FUMEE ITEM NUM RO DESCRIPTION 26 B03349 01 PANNEAU HAUT ARRIERE 27 B00711 FLUE BAFFLE 28 L...

Отзывы: